Technical data

Listing and Managing Server Hardware
Listing Cell Processor and Memory Configurations
HP System Partitions Guide: Administration for nPartitions, rev 5.1
334
GSP:CM> PS
This command displays detailed power and hardware configuration status.
You may display detailed power and hardware status for the following items:
B - Cabinet (UGUY)
C - Cell
G - GSP
I - Core IO
Select Device: c
Enter cabinet number: 0
Enter slot number: 0
HW status for Cell 0 in cabinet 0: NO FAILURE DETECTED
Power status: on, no fault
Boot is not blocked; PDH memory is shared
Cell Attention LED is off
RIO cable status: connected
RIO cable connection physical location: cabinet 0, IO bay 1, IO chassis 3
Core cell is cabinet 0, cell 0
PDH status LEDs: ****
CPUs
0 1 2 3
Populated * * * *
Over temperature
DIMMs populated:
+----- A -----+ +----- B -----+ +----- C -----+ +----- D -----+
0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
* * * *
PDC firmware rev 10.0
PDH controller firmware rev 7.6, time stamp: TUE MAY 08 20:42:26 2001
GSP:CM>