Technical data

Listing and Managing Server Hardware
Checking for Power Supply Failures
HP System Partitions Guide: Administration for nPartitions, rev 5.1
361
======================
Power Supply 0 ok
Power Supply 1 ok
Power Supply 2 ok
Notes: N+ = There are one or more spare items (fans/power supplies).
N = The number of items meets but does not exceed the need.
N- = There are insufficient items to meet the need.
? = The adequacy of the cooling system/power supplies is unknown.
#
Checking Power Supply Status [Partition Manager]
This procedure (Complex —> Show Complex Details menu, Power/Cooling
tab) lists power status from Partition Manager.
Step 1. Run Partition Manager (/opt/parmgr/bin/parmgr) or access it from
SAM or a Web browser.
Step 2. Select the Complex —> Show Complex Details menu item.
This displays the Complex Details window.
Step 3. Click the Power/Cooling tab to bring up the panel that contains
information about the status of the power supplies in the complex.