Technical data
nPartition System Overviews
Specifying Cells and I/O Chassis to Commands
HP System Partitions Guide: Administration for nPartitions, rev 5.1
88
• Cell Hardware Location Format
In cell hardware location format, each cell is identified using two
numbers that specify the cabinet and the cell slot with the cabinet
where the cell resides: cabinet/slot.
Both of these cell ID formats specify each cell’s precise physical location
in a server complex. For example, parstatus -c9 and parstatus -c1/1
specify the same cell.
# parstatus -c9
[Cell]
CPU Memory Use
OK/ (GB) Core On
Hardware Actual Deconf/ OK/ Cell Next Par
Location Usage Max Deconf Connected To Capable Boot Num
========== ============ ======= ========= =================== ======= ==== ===
cab1,cell1 active base 4/0/4 8.2/ 0.0 - no yes 1
# parstatus -c1/1
[Cell]
CPU Memory Use
OK/ (GB) Core On
Hardware Actual Deconf/ OK/ Cell Next Par
Location Usage Max Deconf Connected To Capable Boot Num
========== ============ ======= ========= =================== ======= ==== ===
cab1,cell1 active base 4/0/4 8.2/ 0.0 - no yes 1
#
Table 1-7 Cell IDs in Hardware Location Format
Cell Slot 01234567
rp7410
HW Loc Format
0/00/1——————
rp8400
HW Loc Format
0/00/10/20/3————
Superdome
Cabinet 0
HW Loc Format
0/0 0/1 0/2 0/3 0/4 0/5 0/6 0/7
Superdome
Cabinet 1
HW Loc Format
1/0 1/1 1/2 1/3 1/4 1/5 1/6 1/7