A Specifications
Desktop Dimensions
Height
Width
Depth (depth will increase if the computer is equipped with a
port security bracket)
6.6 in
17.65 in
17.8 in
16.7 cm
44.8 cm
45.2 cm
Tower Dimensions
Height
Width
Depth (depth will increase if the computer is equipped with a
port security bracket)
17.65 in
6.6 in
17.8 in
44.8 cm
16.7 cm
45.2 cm
Approximate Weight 35 lb 15.9 kg
Weight Supported (maximum distributed load for Desktop
configuration only)
100 lb 45.5 kg
Temperature Range
Operating
Nonoperating
50° to 95°F
-22° to 140°F
10° to 35°C
-30° to 60°C
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
10,000 ft
30,000 ft
3048 m
9144 m
NOTE Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level;
no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type
and number of options installed.
Heat Dissipation
Maximum
Typical (idle)
1,916 BTU/hr
375 BTU/hr
483 kg-cal/hr
95 kg-cal/hr
Power Supply 115V 230V
ENWW 41