Storage Area Network Configurations for RA8000/ESA12000 on Windows NT-Intel Application Note

SAN Configurations for RA8000/ESA12000 on Windows NT - Intel
Page 18 AARHH6BTE
SAN Configuration 4 Server/Storage Connectivity Rules
Any mix of Windows NT Intel Servers - standalone or clustered, configured for HA or non-HA,
and any mix of Multiple-bus Failover and Transparent Failover storage systems using these
maximums. Assumes all servers configured for HA, 2 FC switches and 2 FC HBAs per server
for HA, an even storage port count, and no EBS ports.
16-port FC Switches, total number of switch ports available for Servers and Storage is 60
Maximum Server Connectivity,
Up to 26 Servers and 2 Storage Systems (8 Active storage ports)
[(64 4 ISL ports 8 storage ports)/2 = 26 servers]
Maximum of 16 servers configured on any one controller pair
Maximum of 8 servers configured on any one active controller host port
Or Maximum Storage Capacity,
Up to 12 Storage Systems (48 Storage Ports) and 6 HA Servers
[64 4 ISL ports 12 server ports = 48 storage ports]
Maximum of 4 active controller host ports per FC HBA
8-port FC Switches, total number of switch ports available for Servers and Storage is 28
Maximum Server Connectivity,
Up to 12 Servers and 1 Storage System (4 storage ports)
[(32 4 ISL ports 4 storage ports)/2 = 12 server ports]
Maximum of 8 servers configured on any active controller host port
Or Maximum Storage Capacity,
Up to 6 Storage Systems (22 storage ports) and 3 HA Servers
[32 4 ISL ports 6 server ports = 22 storage ports]
Maximum of 4 active controller host ports per FC HBA
For dual path high availability, HSG80 controller pairs are configured in Multiple-Bus Failover
Mode, for single path servers (non-HA) controllers are configured in Transparent Failover Mode
EBS Integration Supported
SAN Configuration 4 Fabric Rules
Total Switches = 4, 16-port or 8-port
Maximum Switch Hops (nominal) = 1 in each path
Maximum Switch Hops (worst case ) = 1 in each path
Maximum number of ISLs between the two switch in each path = 15
Maximum Distances:
Up to 500 meters per FC cable segment, 1.5 km total server to storage when using 50 micron
multi-mode fibre optic cable. Refer to general Fabric rules for other cable types
Up to 10 km per inter-switch link, 11 km total server to storage when using 9 micron single
mode fibre optic cable and long wave GBICs
SAN Configuration 4 Notes
Each FC Switch within a path must have a unique domain number (Domain_ID)
Uses Compaq Secure Path for Windows NT (minimum version 2.2)
One instance of the Secure Path Manager is required for each standalone server or each pair of
clustered servers. One instance can control 2 paths on up to 4 storage systems. All instances can
be run from a single Client if desired
Each server is configured for access to two paths and two controller ports, using either Port 1 of
both controllers or Port 2 of both controllers
For servers accessing controller host port 1 use LUN number and offset values in the range of 0
99, for controller host port 2 use number and offset values in the range 100 -199
Depending on the specific number of servers and storage systems utilized in this SAN
configuration, it is possible to exceed the available total number of connection name entries in a
storage system. (See Windows NT Server/Storage Rules). This situation can be avoided by using