Storage Area Network Configurations for RA8000/ESA12000 on Windows NT-Intel Application Note

SAN Configurations for RA8000/ESA12000 on Windows NT - Intel
Page 24 AARHH6BTE
SAN Configuration 6 Server/Storage Connectivity Rules
Any mix of Windows NT Intel Servers - standalone or clustered, and storage systems using these
maximums. Assumes 1 FC HBA per server, an even storage port count, and no EBS ports.
16-port FC Switches, total number of switch ports available for Servers and Storage is 52
Maximum Server Connectivity,
Up to 40 Servers and 3 Storage Systems (12 storage ports/6 Active, 6 Standby)
[64 12 ISL ports 12 storage ports = 40 server ports]
Maximum of 16 servers configured on any one controller pair
Maximum of 8 servers configured on any active controller host port
Or Maximum Storage Capacity,
Up to 12 Storage Systems (46 storage ports/23 Active, 23 Standby) and 6 Servers
[64 12 ISL ports 6 server ports = 46 storage ports]
Maximum of 4 active controller host ports per FC HBA
8-port FC Switches, total number of switch ports available for Servers and Storage is 20
Maximum Server Connectivity,
Up to 16 Servers and 1 Storage System (4 storage ports/2 Active, 2 Standby)
[32 12 ISL ports 4 storage ports = 16 server ports]
Maximum of 16 servers configured on any one controller pair
Maximum of 8 servers configured on any active controller host port
Or Maximum Storage Capacity,
Up to 4 Storage Systems (16 storage ports/8 Active, 8 Standby) and 4 Servers
[32 12 ISL ports 4 server ports = 16 storage ports]
Maximum of 4 active controller host ports per FC HBA
All HSG80 array controllers configured in Transparent Failover Mode
NOTE
High availability storage using Secure Path for Windows
NT and Controller Multiple-bus Failover Mode is currently
not supported in this configuration.
SAN Configuration 6 Fabric Rules
Total Switches = 4, 16-port or 8-port
Maximum Switch Hops (nominal ) = 1
Maximum Switch Hops (worst case ) = 2
Maximum number of ISLs between any two switches = 15
Maximum Distances:
Up to 500 meters per FC cable segment, 1.5 km total server to storage (2.0 km worst case)
when using 50 micron multi-mode fibre optic cable. Refer to general Fabric rules for other
cable types
Up to 10 km per inter-switch link, 11 km total server to storage (21 km worst case) when
using 9 micron single mode fibre optic cable and long wave GBICs
SAN Configuration 6 Notes
Each FC Switch must have a unique domain number (Domain_ID)
When configured with greater than 4 Windows NT Servers per active controller host port,
classified as an NT Extended Configuration (refer to the StorageWorks Windows NT Platform
Kit FC Software Setup Utility
For servers accessing controller host port 1 use LUN number and offset values in the range of 0
99, for controller host port 2 use number and offset values in the range 100 -199
Depending on the specific number of servers and storage systems utilized in this SAN
configuration, it is possible to exceed the available total number of connection name entries in a