Manual

DescriptionParameter
Possible values:
TrustByCert—If you use this value, you must define the CERTLIST
parameter to enable access to the server.
TrustByName—If you use this value, you must define the XENAMELIST.
TrustByAll—HP does not recommend using this value because of possible
negative security consequences.
CAUTION: The accepted values are case-sensitive and must be
capitalized as shown. Failure to do so prevents the trust relationship
from being set up properly during installation and might affect access
to the web server.
Enables you to provide a list of certificate files or servers where certificates
can be obtained for trust relationships for the HP Systems Management
Homepage. (Applies to Linux SPP only.)
CERTLIST
Possible values:
Certificate file name or Server DNS name
Enables you to provide a list of servers, separated by semicolons, for trust
relationships for the HP Systems Management Homepage. (Applies to
Linux SPP only.)
XENAMELIST
This parameter is valid only if the TRUSTMODE parameter is set to
TrustByName. (Applies to Linux SPP only.)
Possible values:
Server DNS name
The hp_qla2x00 QLogic Fibre Channel Driver uses this parameter to
determine the failover mode to use. (Applies to Linux SPP only.)
HPQLA2X00FO
Possible values:
SinglePath
SecurePath
QLogicFailure
NOTE: No default value
The hp_qla2x00 QLogic Fibre Channel Driver uses this parameter to
determine whether to skip detection of third-party storage. (Applies to Linux
SPP only.)
HPQLA2X00FORCE
Possible values:
Y, N (default)
Provides the user name credentials for the OA associated with VC. You
must define a value of these variables before the HOST variable in the
[TARGETS] section. This parameter applies only for VC firmware.
OAUID
You can also use OAUSER or OAUSERNAME.
Possible values:
User can define the OAUID variable multiple times before each HOST
variable.
Provides the password credentials for the OA associated with VC. You
must define a value of these variables before the HOST variable in the
[TARGETS] section. This parameter applies only for VC firmware.
OAPWD
You can also use OAPASSWORD.
Possible values:
User can define OAPWD variable multiple times before each HOST variable.
90 Using legacy scripts to deploy updates