Owner's manual

1. Pull the battery retaining clip away (1).
Figure 70 Installing backplane battery
2. Place the bat tery into the holder (2) .
3. Reattach the rear top cover (see Rear top cover).
System memory
CAUTION:
Remove powe
r
to the server by disconnecting the power cord before removing or installing system
memory.
See for the location of the two 240–pin dual inline memory module (DIMM) sockets. The sockets support
up to 8 GB dual channel D DR2 533/667 MHz u nbuffered low-prole (1.2 inch) synchronous dynamic
random access mem ory (SDRAM) with error-correcting code (ECC) s upport.
Figure 71 Location of DIMM sockets
The four D IMM sockets are respectively CH_B DIMM1, CH_B DIMM0, CH_A DIMM1 and CH_A
DIMM0. All the low-prole DIMMs must be the same speed. See the table below for installing one or
more modules in the sockets.
HP StorageWorks 1000i Virtual Library System
89