Instruction Manual
Fabric View
3–96 Web Tools Version 3.0.x/4.0.x User Guide
AL_PA Level Zoning
AL_PA Level Zoning is a replacement for QuickLoop Zoning. With AL_PA Level
Zoning, only members of a QuickLoop can be a member of the zone. Zone members
are specified through their AL_PA.
Figure 3–40 shows a typical AL_PA Device Alias tab of the AL_PA Zoning window.
The following tabs are provided in the AL_PA Level Zoning menu:
• Device Alias
• Device Zone
•QuickLoop
• Device Config
Ref Zone Click to refresh the local zoning database copied
from the switch. This button automatically flashes
red/gray if the fabric zoning data is changed by
another client.
A/D WWN Click to add/delete a WWN to/from all the aliases,
zones, and FA zones defined.
Rpl WWN Click to replace a WWN with another one in all
aliases, zones, and FA zones defined.
Ok Applies the changes to the switch and exits the
switch.
Apply Click to apply all changes made including changes
made on other tabs in the view. Changes cannot
be cancelled once they are applied.
Close Click to exit the window without making any
changes to the switch.
Clr All Select to clear the zoning database, disable the
effective configuration (if there is one), and then
commit to the switch.
Table 3–35: WWN Config Tab Fields (Continued)