Instruction Manual

Switch View
4–16 Web Tools Version 3.0.x/4.0.x User Guide
The Configure Threshold tab is shown in Figure 4–8.
Figure 4–8: Configure Threshold tab with AL_PA Class selected in Performance
view
Use the Configure Thresholds tab to view and configure End-to-End thresholds for the
Performance class currently selected in the organizational tree on the left side of the
window.
NOTE: You must define the SID/DID pair through the Performance Monitor before you can
monitor the threshold in the End-to-End class. For more information on the Performance
Monitor, see “Performance Monitor” on page 4–26 of this document, or the HP StorageWorks
Advanced Performance Monitoring Version 3.0.x/4.0.x User Guide.