Instruction Manual

Port View
5–19Web Tools Version 3.0.x/4.0.x User Guide 5–19
BR Min Indicates the lower limit at which SFP meets its
specifications (in units of 1 percent below nominal baud
rate).
Options May indicate any of the following:
Loss of Signal
Loss of Signal Inverted
Transmission Fault
Transmission Disable
Length 9u Indicates the length of link using single mode fiber cable.
Length 50u Indicates the length of link using 50um multi-mode fiber
cable.
Length 625u Indicates the length of link using 62.5um multi-mode fiber
cable.
Length Cu Indicates the minimum length of link using copper cable.
Vendor Name Displays the name of the SFP vendor.
Vendor OUI Displays the unique identifier for the SFP vendor.
Vendor P/N Displays the SFP vendor part number.
Vendor Rev Displays the vendor revision number.
Serial No. Displays the vendor serial number.
Date Code Displays the vendor date code.
Smart SFP Data (only displays if a smart SFP is present):
Temperature Displays the module temperature (in Centigrade).
Rx Power Displays the received optical power in microwatts.
Tx Power Displays the transmitted optical power in microwatts
(longwave only).
Current Displays the laser diode drive current in mAmps.
Table 5–6: SFP Tab Fields (Continued)