For tests that can be aborted, the Start Test button changes to Abort Test.
Figure 19 Abort Test button
After the Abort Test button is clicked, L&TT will attempt to abort the test, which can take 10 – 20
seconds or more. Once the abort button has been clicked, the button is greyed out and cannot be
clicked again.
Running multiple instances of L&TT
You can run multiple instances of L&TT on the same computer, which can be useful for analyzing
multiple devices or multiple components of a device at the same time. Although L&TT will let you
access the same device from multiple instances of L&TT, this is not recommended because it can
cause unpredictable results.
A warning dialog will be displayed when you start the second and subsequence instances of L&TT.
If you continue, L&TT will display the Multiple Tool Instance dialog, in which you can name this
instance of L&TT. The instance name will be displayed in the window banner of the L&TT main
window and will be used to create a unique subdirectory for the log files associated with this
instance of L&TT. If you are running L&TT from removable media, The Multiple Tool Instance dialog
will also allow you to select the path to the log file directory.
Using a report or support ticket
A major feature of L&TT is the ability to generate reports and support tickets. In the event of a
hardware problem, a report or support ticket can provide vital information to help diagnose and
resolve the problem. Reports and support tickets can be generated on all operating systems
Using a report or support ticket 43