Specifying SCSI Addresses
Viewing the Current SCSI Address Settings
1 2 3 4
ADMIN*
PSWD 000-000-000
SCSI IDs*
VIEW IDs*
To view the current SCSI address settings:
1. Verify that the drive status displays (if not, press
CANCEL
until it does).
2. Press
NEXT
until
ADMIN*
displays, then press
ENTER
.
3. Enter the three-part numerical password (see “Entering the
Administration Menu Password” on page 4-7).
4. Press
NEXT
until
SCSI IDs*
displays, then press
ENTER
.
5.
SET IDs*
displays. Press
NEXT
until
VIEW IDs*
displays, then press
ENTER
.
6.
BUS0 LIB ID#
or
BUS# DRV * ID *
displays. (BUS0 LIB ID # stands
for the current SCSI ID of the robotics controller.
BUS# DRV # ID # is the current SCSI ID setting for the displayed drive
number and its associated BUS#.)
Press
NEXT
or
PREV
to scroll through the current address settings.
7. Press
CANCEL
until the next operation to perform displays, or until the
drive status (library “ready” state) displays.
Setting the SCSI Addresses
1 2 3 4
ADMIN*
PSWD 000-000-000
SCSI IDs*
SET IDs*
A SCSI address is required for the robotics controller and each tape drive.
For more information, see Table 4-2, “Default SCSI Address Settings” on page
4-9, and the section “Viewing the Current SCSI Address Settings” on page
4-10.
To change the current SCSI address settings:
1. Verify that the drive status displays (if not, press
CANCEL
until it does).
2. Press
NEXT
until
ADMIN*
displays, then press
ENTER
.
3. Enter the three-part numerical password (see “Entering the
Administration Menu Password” on page 4-7).
4. Press
NEXT
until
SCSI IDs*
displays, then press
ENTER
.