Manual

4-18
Library Operation
Loading Cartridges Into the Library
7. Insert tape cartridges one at a time into the desired storage slots so that
the brand name printed on the top of the cartridge faces up and the tape
label faces out (see Figure 4-4). Storage slots are labeled by number (see
the diagram located inside the bulk load access door).
8. Shut the bulk load access door. The Inventory Check test begins when the
door is completely closed.
NOTE The Inventory Check test inventories the tape bar code labels and storage
slot locations, and stores them in library memory. This process takes about
one minute.
Security Configurations
Some security configurations may prevent the bulk load access door from
being released. If a security option is enabled, SECURITY ENABLED displays.
If the drives contain cartridges, DRIVE(s) FULL displays after the RELEASE
DOOR option is chosen.
In some situations it may be necessary to override a security option and open
the bulk load access door. To open the door when a security option prevents
the door from being released, use the OVERRIDE DOOR option under the
ADMIN* menu (see Figure 4-4).