Library Operation
Clearing a Drive Cleaning Error
DRV # ON GOOD displays, where “#” is the drive number and ON GOOD
is flashing.
6. Press
NEXT
until DRV # OFF FAILED displays then press
ENTER
.
7. CHANGE CONFIRMED displays briefly, then ONLINE REPAIR*
displays. Press
ENTER
.
8. DRIVE POWER* displays.
9. Press
NEXT
or
PREV
until DRIVE STATUS displays, then press
ENTER
.
10. Press
NEXT
or
PREV
until DRV # OFF FAILED displays (where “#” is the
number of the drive that was just taken off-line) then press
ENTER
.
11. DRV # OFF FAILED displays, where “#” is the drive number and “OFF
FAILED” is flashing.
12. Press
NEXT
until DRV # ON GOOD displays, then press
ENTER
.
13. SETTING UP DRIVE displays briefly while the drive communication
tests run, then CHANGE CONFIRMED displays briefly, then ONLINE
REPAIR* displays.
14. Press
CANCEL
twice to return to the drive numbers and status indicators
(“ready” state).
15. Try reading the damaged tape again.
If the tape can be read, back up data from the damaged cartridge to
another tape cartridge and discard the damaged one.
If the tape cannot be read, call a service representative.
If the tape can be read, back up data from the damaged cartridge to
another tape cartridge and discard the damaged one.