User's Manual

Specication
Description
EMC immunity
IEC 61000-4-2 S
everity Level 3 for Electrostatic Discharge
IEC 61000-4-3
Severity Level 3 for Radiated Fields
IEC 61000-4-4
Severity Level 3 for Fast T ransients
IEC 61000-4-5
Severity Level 3 for Surge V oltage
IEC 61000-4 -
6 Conducted Emissions
IEC 61000-4 -
11 Voltage Variations
EN 61000-4-
12 Oscillatory Waves Immunity
EN 61000-3-
2 Limits for Harmonic Current Emissions
EN 61000-3
-3 JEIDA
Sy stem architecture Nonblocking shared-memory switch
ANSI protocol FC-PH (FC Physical and Signalling Interface standard)
Modes of operation
FC Class 2, Class 3, and Class F
Maximum frame size
2112-byte
Port-to-port la tency
Less than 2 microseconds w ith no contention (destination
port is free)
Weight and physical dimensions
nl
Table 1 9 l
ists physical prop er ties.
Table 19 8Gb SAN Switch physical d imensions
Dimensio n
Measurement
Height
29.3 mm (1.15 in)
Width
208 mm (8.19 in)
Depth
280mm(11.02in)
Weight 1.27 kg (2.8 lb)
Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions beyond those
for which it was tested. The ranges specied in Table 20 list the acceptable environment for both
operating and nonoperating conditions.
Table 20 Environmental requirements
Condition Acceptable range during operation
Acceptable rang e during
non-operation
Ambient
temperature
104°F/40 °C at sea level, derated 1 C
per 1000 ft above sea level
-40°Cto70°Cwithmaximumrateof
change of 20 C /hr
Humidity
5% to 90% relative humidity,
non-condensing
50%to80%relativehumidity,
non-condensing
Altitude
0to10,000ft(3km)abovesealevel 0to40,000ft(12km)abovesealevel
Shock 40 G, 2mS duration
14 0 G , 2 m S ,
Vibration
0.5G,10500Hz 2.0G,5500Hz
Airow 4 7 cubic ft/minute
None required
50
SAN Switch technical specications