Ensuring proper ventilation
Proper ventilation for the system is important for workstation operation. Follow these guidelines:
Operate the workstation on a sturdy, level surface.
Provide at least 15.24 cm (6 inches) of clearance at the front and back of the workstation. (Workstation
models vary.)
Be sure that the ambient air temperature falls within the environmental specications listed in this
documen
t.
NOTE: The ambient upper limit of 35°C (95°F) is only good up to 1524 m (5000 ft) elevation. There is a
1°C (33.8°F) per 304.8 m (1000 f
t) derating above 1524 m (5000 ft). So, at 3,048 m (10,000 ft), the
upper ambient air temperature limit is 30°C (86°F).
For cabinet installation, be sure that adequate cabinet ventilation and the ambient temperature within
the cabinet doe
s not exceed specied limits.
Never restrict the incoming or outgoing airow of the workstation by blocking any vents or air intakes,
as sho
wn in the following gure.