SMART Error Eject
When a SMART notification is received from a device, it is currently treated as a soft
error - the notification is passed to the host and operations continue. A new CLI switch
at the controller level changes this behavior. When this switch is enabled, drives in a
normalized and redundant set that report a smart error are removed from that set.
Smart errors that are reported by drives in a non-redundant or non-normal set continue
to handle this condition as a recovered error.
If the smart error eject state is disabled, all smart errors are reported as recovered
errors. The recovered error report contains the ASC = 0x5D, the ASC for all smart
errors, and the appropriate ASCQ. The default value for this feature is DISABLE.
CLI command syntax:
HSG> set this_controller smart_error_eject = [enable|disable]