FC Configuration Procedures
5–13HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and
Configuration Guide
5–13
6. Set the topology for the controller. If both ports are used, set topology for both
ports:
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
If the controller is not factory-new, it may have another topology set, in which
case these commands will result in an error message. If this happens, first take
both ports offline, then reset the topology:
SET THIS PORT_1_TOPOLOGY=OFFLINE
SET THIS PORT_2_TOPOLOGY=OFFLINE
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
Restart the Controller
7. Restart the controller, using the following command:
RESTART THIS
It takes about a minute for the CLI prompt to come back after a RESTART command.
Set Time and Verify All Commands
8. Set the time on the controller by entering the following syntax:
SET THIS TIME=DD-MMM-YYYY:HH:MM:SS
9. Use the FRUTIL utility to set up the battery discharge timer. Enter the following
command to start FRUTIL:
RUN FRUTIL
When FRUTIL asks if you intend to replace the battery, answer “Y”:
Do you intend to replace this controller's cache battery? Y/N [N] Y
FRUTIL will print out a procedure, but will not give you a prompt. Ignore the
procedure and press Enter.
10. Set up any additional optional controller settings, such as changing the CLI
prompt. See the
SET THIS CONTROLLER/OTHER CONTROLLER command in the StorageWorks
HSG80 Array Controller ACS Version 8.7 CLI Reference Guide for the format of
optional settings. Perform this step on both controllers.
11. Verify that all commands have taken effect by entering the following command:
SHOW THIS