HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide

Table Of Contents
SWCC Agent in TruCluster Environment
C–17HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and
Configuration Guide
C–17
NOTE: When you enter the command to set multiple-bus failover and copy the configuration
information to the other controller, the other controller will restart. The restart may set off the
audible alarm (which is silenced by pressing the button on the environmental monitoring unit
(EMU)). The command line interpreter (CLI) will display an event report, and continue reporting
the condition until you clear the condition with the clear cli command.
HSG80> set multibus copy = this
HSG80> show this
Controller:
HSG80 ZG02700662 Software V85F-0, Hardware E05
NODE_ID = 5000-1FE1-0006-3F10
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
Configured for MULTIBUS_FAILOVER with ZG02700619
In dual-redundant configuration
Device Port SCSI address 7
Time: 01-MAR-2001 17:48:32
Command Console LUN is lun 0 (NOIDENTIFIER)