HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide
Table Of Contents
- HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide
- About this Guide
- 1- Planning a Subsystem
- Defining Subsystems
- What is Failover Mode?
- Selecting a Cache Mode
- Enabling Mirrored Caching
- What is the Command Console LUN?
- Determining Connections
- Assigning Unit Numbers
- What is Selective Storage Presentation?
- 2- Planning Storage Configurations
- Where to Start
- Determining Storage Requirements
- Configuration Rules for the Controller
- Addressing Conventions for Device PTL
- Choosing a Container Type
- Creating a Storageset Profile
- Planning Considerations for Storageset
- Changing Characteristics through Switches
- Specifying Storageset and Partition Switches
- Specifying Initialization Switches
- Specifying Unit Switches
- Creating Storage Maps
- 3- Preparing the Host System
- Installing RAID Array Storage System
- Making a Physical Connection
- Preparing LUNs for Access by Tru64 UNIX FileSystem
- DECsafe Available Server Environment (ASE)
- HSG80 Units and Tru64 UNIX Utilities
- Solution Software Upgrade Procedures
- New Features, ACS 8.7 for Tru64
- 4- Installing and Configuring HSG Agent
- 5- FC Configuration Procedures
- Establishing a Local Connection
- Setting Up a Single Controller
- Setting Up a Controller Pair
- Configuring Devices
- Configuring Storage Containers
- Assigning Unit Numbers and Unit Qualifiers
- Configuration Options
- Verifying Storage Configuration from Host
- 6- Using CLI for Configuration
- 7- Backing Up, Cloning, and Moving Data
- A- Subsystem Profile Templates
- Storageset Profile
- Storage Map Template 1 for the BA370 Enclosure
- Storage Map Template 2 for the second BA370 Enclosure
- Storage Map Template 3 for the third BA370 Enclosure
- Storage Map Template 4 for the Model 4214R Disk Enclosure
- Storage Map Template 5 for the Model 4254 Disk Enclosure
- Storage Map Template 6 for the Model 4310R Disk Enclosure
- Storage Map Template 7 for the Model 4350R Disk Enclosure
- Storage Map Template 8 for the Model 4314R Disk Enclosure
- Storage Map Template 9 for the Model 4354R Disk Enclosure
- B- Installing, Configuring, and Removing the Client
- C- SWCC Agent in TruCluster Environment
- SWCC Overview
- Running the SWCC Agent on a V4.0G Cluster
- Running the SWCC Agent under ASE Services
- Running the SWCC Agent on a V5.x Cluster
- Problems with Running the Agent on Multiple Clusters
- Configure the Controller
- Use Multiple-Bus Failover Mode
- Verify That the HSG80/HSG60 Unit Offsets Are Zero
- Install and Run the Agent on One Cluster Member
- Example of Installing the Agent on a Cluster Member
- Create the CAA Action Script
- Create the CAA Resource
- Glossary
- Index
Glossary
Glossary–6 HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and
Configuration Guide
DWZZA
A StorageWorks SCSI bus signal converter used to connect 8-bit
single-ended devices to hosts with 16-bit differential SCSI adapters.
This converter extends the range of a single-ended SCSI cable to the
limit of a differential SCSI cable.
DWZZB
A StorageWorks SCSI bus signal converter used to connect a variety of
16-bit single-ended devices to hosts with 16-bit differential SCSI
adapters.
ECB
External cache battery. The unit that supplies backup power to the
cache module in the event the primary power source fails or is
interrupted.
ECC
Error checking and correction.
EDC
Error detection code.
EIA
The abbreviation for Electronic Industries Association. EIA is a
standards organization specializing in the electrical and functional
characteristics of interface equipment.
EMU
Environmental monitoring unit. A unit that provides increased
protection against catastrophic failures. Some subsystem enclosures
include an EMU which works with the controller to detect conditions
such as failed power supplies, failed blowers, elevated temperatures,
and external air sense faults. The EMU also controls certain cabinet
hardware including DOC chips, alarms, and fan speeds.
ESD
Electrostatic discharge. The discharge of potentially harmful static
electrical voltage as a result of improper grounding.
extended
subsystem
A subsystem in which two cabinets are connected to the primary
cabinet.
external cache
battery
See ECB.
F_Port
A port in a fabric where an N_Port or NL_Port may attach.
fabric
A group of interconnections between ports that includes a fabric
element.
failback
The process of restoring data access to the newly-restored controller in
a dual-redundant controller configuration. See also failover.