HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide
Table Of Contents
- HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide
- About this Guide
- 1- Planning a Subsystem
- Defining Subsystems
- What is Failover Mode?
- Selecting a Cache Mode
- Enabling Mirrored Caching
- What is the Command Console LUN?
- Determining Connections
- Assigning Unit Numbers
- What is Selective Storage Presentation?
- 2- Planning Storage Configurations
- Where to Start
- Determining Storage Requirements
- Configuration Rules for the Controller
- Addressing Conventions for Device PTL
- Choosing a Container Type
- Creating a Storageset Profile
- Planning Considerations for Storageset
- Changing Characteristics through Switches
- Specifying Storageset and Partition Switches
- Specifying Initialization Switches
- Specifying Unit Switches
- Creating Storage Maps
- 3- Preparing the Host System
- Installing RAID Array Storage System
- Making a Physical Connection
- Preparing LUNs for Access by Tru64 UNIX FileSystem
- DECsafe Available Server Environment (ASE)
- HSG80 Units and Tru64 UNIX Utilities
- Solution Software Upgrade Procedures
- New Features, ACS 8.7 for Tru64
- 4- Installing and Configuring HSG Agent
- 5- FC Configuration Procedures
- Establishing a Local Connection
- Setting Up a Single Controller
- Setting Up a Controller Pair
- Configuring Devices
- Configuring Storage Containers
- Assigning Unit Numbers and Unit Qualifiers
- Configuration Options
- Verifying Storage Configuration from Host
- 6- Using CLI for Configuration
- 7- Backing Up, Cloning, and Moving Data
- A- Subsystem Profile Templates
- Storageset Profile
- Storage Map Template 1 for the BA370 Enclosure
- Storage Map Template 2 for the second BA370 Enclosure
- Storage Map Template 3 for the third BA370 Enclosure
- Storage Map Template 4 for the Model 4214R Disk Enclosure
- Storage Map Template 5 for the Model 4254 Disk Enclosure
- Storage Map Template 6 for the Model 4310R Disk Enclosure
- Storage Map Template 7 for the Model 4350R Disk Enclosure
- Storage Map Template 8 for the Model 4314R Disk Enclosure
- Storage Map Template 9 for the Model 4354R Disk Enclosure
- B- Installing, Configuring, and Removing the Client
- C- SWCC Agent in TruCluster Environment
- SWCC Overview
- Running the SWCC Agent on a V4.0G Cluster
- Running the SWCC Agent under ASE Services
- Running the SWCC Agent on a V5.x Cluster
- Problems with Running the Agent on Multiple Clusters
- Configure the Controller
- Use Multiple-Bus Failover Mode
- Verify That the HSG80/HSG60 Unit Offsets Are Zero
- Install and Run the Agent on One Cluster Member
- Example of Installing the Agent on a Cluster Member
- Create the CAA Action Script
- Create the CAA Resource
- Glossary
- Index
![](/manual/hp/tru64-unix-5-1/hsg80-acs-solution-software-version-87-for-compaq-tru64-unix-installation-and-configuration-guide/images/img-286.png)
Index
HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and
Configuration Guide
Index–5
transparent fafilover 1–23
SCSI version factor
1–18
online help
SWCC
B–13
options
for mirrorsets
2–29
for RAIDsets
2–28
initialize
2–30
other controller
1–3
P
pager notification B–13
configuring
B–13
partitions
assigning a unit number
fabric topology
5–22
creating on a LUN using disklabel
3–7
defining
2–27
planning considerations
2–26
guidelines
2–27
performance
2–22
Physical connection, making
3–6
planning
2–1
overview
2–16
striped mirrorsets
2–25
stripesets
2–19
Planning a subsystem
1–1
planning configurations
where to start
2–2
planning considerations
2–22
planning storage
containers
2–14
planning storagesets
characteristics
changing switches
2–28
enabling switches
2–28
initialization switch
2–27
storagest switch
2–27
unit switch
2–27
switches
initialization
2–29
storageset
2–28
preferring units
multiple-bus failover
fabric topology
5–23
profiles
creating
2–16
description
2–16
storageset
A–1
example
A–2
R
RAIDset switches
changing
fabric topology
5–26
RAIDsets
choosing chunk size
2–30
maximum membership
2–24
planning considerations
2–22
important points
2–23
switches
2–28
read caching
enabled for all storage units
1–10
general description
1–10
read requests
decreasing the subsystem response time with
read caching
1–10
read-ahead caching
1–10
enabled for all disk units
1–10
removing
Client
B–12
request rate
2–30
requirements
host adapter installation
3–6
restricting host access
disabling access paths
multiple-bus failover
1–24
transparent failover
1–23
multiple-bus failover
1–24
separate links
transparent failover
1–22
transparent failover
1–21
S
SAVE_CONFIGURATION 2–32