HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide
Table Of Contents
- HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide
- About this Guide
- 1- Planning a Subsystem
- Defining Subsystems
- What is Failover Mode?
- Selecting a Cache Mode
- Enabling Mirrored Caching
- What is the Command Console LUN?
- Determining Connections
- Assigning Unit Numbers
- What is Selective Storage Presentation?
- 2- Planning Storage Configurations
- Where to Start
- Determining Storage Requirements
- Configuration Rules for the Controller
- Addressing Conventions for Device PTL
- Choosing a Container Type
- Creating a Storageset Profile
- Planning Considerations for Storageset
- Changing Characteristics through Switches
- Specifying Storageset and Partition Switches
- Specifying Initialization Switches
- Specifying Unit Switches
- Creating Storage Maps
- 3- Preparing the Host System
- Installing RAID Array Storage System
- Making a Physical Connection
- Preparing LUNs for Access by Tru64 UNIX FileSystem
- DECsafe Available Server Environment (ASE)
- HSG80 Units and Tru64 UNIX Utilities
- Solution Software Upgrade Procedures
- New Features, ACS 8.7 for Tru64
- 4- Installing and Configuring HSG Agent
- 5- FC Configuration Procedures
- Establishing a Local Connection
- Setting Up a Single Controller
- Setting Up a Controller Pair
- Configuring Devices
- Configuring Storage Containers
- Assigning Unit Numbers and Unit Qualifiers
- Configuration Options
- Verifying Storage Configuration from Host
- 6- Using CLI for Configuration
- 7- Backing Up, Cloning, and Moving Data
- A- Subsystem Profile Templates
- Storageset Profile
- Storage Map Template 1 for the BA370 Enclosure
- Storage Map Template 2 for the second BA370 Enclosure
- Storage Map Template 3 for the third BA370 Enclosure
- Storage Map Template 4 for the Model 4214R Disk Enclosure
- Storage Map Template 5 for the Model 4254 Disk Enclosure
- Storage Map Template 6 for the Model 4310R Disk Enclosure
- Storage Map Template 7 for the Model 4350R Disk Enclosure
- Storage Map Template 8 for the Model 4314R Disk Enclosure
- Storage Map Template 9 for the Model 4354R Disk Enclosure
- B- Installing, Configuring, and Removing the Client
- C- SWCC Agent in TruCluster Environment
- SWCC Overview
- Running the SWCC Agent on a V4.0G Cluster
- Running the SWCC Agent under ASE Services
- Running the SWCC Agent on a V5.x Cluster
- Problems with Running the Agent on Multiple Clusters
- Configure the Controller
- Use Multiple-Bus Failover Mode
- Verify That the HSG80/HSG60 Unit Offsets Are Zero
- Install and Run the Agent on One Cluster Member
- Example of Installing the Agent on a Cluster Member
- Create the CAA Action Script
- Create the CAA Resource
- Glossary
- Index
![](/manual/hp/tru64-unix-5-1/hsg80-acs-solution-software-version-87-for-compaq-tru64-unix-installation-and-configuration-guide/images/img-41.png)
Planning a Subsystem
1–18 HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and
Configuration Guide
Figure 1–12: LUN presentation to hosts, as determined by offset
Offsets other than the default values can be specified. For example, unit D17 would be
visible to a host connection on port 1 that had an offset of 10 as LUN 7 (unit number
of 17 minus offset of 10). The unit would not be visible to a host connection with a
unit offset of 18 or greater, because that offset is not within the unit’s range (unit
number of 17 minus offset of 18 is a negative number).
Similarly, unit D127 would be visible to a host connection on port 2 that had an offset
of 120 as LUN 7 (unit number of 127 minus offset of 120). The unit would not be
visible to a host connection with a unit offset of 128 or greater, because that offset is
not within the unit’s range (unit number of 127 minus offset of 128 is a negative
number).
An additional factor to consider when assigning unit numbers and offsets is SCSI
version. If the SCSI_VERSION switch of the
SET THIS_CONTROLLER/OTHER_CONTROLLER
command is set to SCSI-3, the CCL is presented as LUN 0 to every connection,
superseding any unit assignments. The interaction between SCSI version and unit
numbers is explained further in the next section.
In addition, the access path to the host connection must be enabled for the connection
to access the unit. See “Restricting Host Access in Transparent Failover Mode,” page
1–21.
Controller
units
Host
connection 1
Offset: 0
Host
connection 2
Offset: 20
Host
connection 3
Offset: 100
LUN 0
LUN 1
LUN 2
LUN 3
LUN 20
LUN 21
LUN 0
LUN 1
LUN 0
LUN 1
LUN 2
LUN 30
LUN 31
D0
D1
D2
D3
D20
D21
D100
D101
D102
D130
D131
CXO6455B