Programming instructions
Chapter 4 121
Field Replaceable Units
FRU Removal and Replacement
Voltage Regulator Modules
This section explains how to remove and replace the voltage regulator modules (master 
and slave), which are connected to the system board in the B2000 workstation.
Removing a Voltage Regulator Module
WARNING
To prevent injury, unplug the workstation’s power cord from the 
electrical outlet before removing the voltage regulator modules.
Perform the following steps to remove a voltage regulator module:
1. Open the left side panel of the workstation as shown in the section “Opening the Left 
Side Panel.”
2. Remove the four T-15 Torx screws from the rear of the chassis that hold the power 
supply in place, as shown in Figure 4-47.
Figure 4-47. Screws Holding the Power Supply in Place
NOTE
The two voltage regulator modules are connected to the bottom of the system 
board, behind the power supply. So, in the next step, you must move the 
power supply to the right in order to access the voltage regulator modules. 
Note that you do not need to disconnect the power supply’s cables from the 
system board, nor remove the power supply entirely from the workstation 
chassis in order to access the voltage regulator modules.
3. Slide the power supply to the right, towards the front of the workstation, until the hook 
on the bottom of the power supply disengages from the support strap in the chassis 
floor. (You do not need to disconnect the power supply’s power cables from the system 
board, nor remove the power supply entirely from the workstation chassis.)
Four T-15
Torx Screws
Power Supply