Programming instructions
86 Chapter 4 
Field Replaceable Units
FRU Removal and Replacement
FRU Removal and Replacement
The procedures in this section describe how to remove and replace (install) field
replaceable units (FRUs). Observe any notices and prerequisites before removing an FRU.
Before performing any FRU removal or replacement procedure, you 
must
 do the 
following:
1. Power off the workstation, the monitor, and any peripheral devices. 
NOTE
There is no need to manually shutdown the HP-UX operating system on the 
workstation before switching it off. When the front panel power switch is 
pressed to off, the workstation automatically shuts down the operating 
system before terminating the power. Wait for the system to completely 
shutdown and power off before disconnecting the power cord.
CAUTION
Unplugging the power cord while HP-UX is running can damage system files.
2. Unplug the workstation’s power cord and the power cord of any peripheral devices from 
AC wall outlets.
3. Unplug the workstation’s power cord from the AC input connector on the rear of the 
workstation.
4. Disconnect any external cables from the connectors on the rear of the workstation.
5. Attach a static-grounding wrist strap to your wrist. Attach the sticky end of the wrist 
strap to bare metal on the rear panel of the workstation.
6. Lay the workstation on a flat stable surface, such as a table top or floor. To protect 
against scratches, remove miscellaneous debris and preferably use an ESD mat to 
cushion the workstation.
CAUTION
Follow normal ESD anti-static precautions when handling the workstation or 
any of its components. (See the section titled “Electrostatic Discharge (ESD) 
Precautions” on page 177.) Failure to do so can cause component degradation 
or failure.
7. If installed, remove any locking device from the security loop on the rear of the 
workstation.