Owner manual

236 HP VMA SAN Gateway Users Guide AM456-9026A
Trap Information Table
process-exit: A process in the system unexpectedly exited.
unexpected-shutdown: Unexpected system shutdown.
Trap Name Threshold Value Unit Description Solution Sev.
array-data-plane-
ready
State Change 0 or 1 An Array data plane
available state change
has occurred. The old
value and new values
are supplied. A value
of 0 = not ready, 1 =
ready.
If the new value is
0, then check the
Array alarms for
more information.
High /
Low
array-fan-change State Change State One or more fans have
changed state on an
Array. The old and
new values are
provided using the
following states: OFF,
Absent, Low, Medium,
or High.
Check Array for
alarms as well as
airflow and
operating
environment.
Medium
array-led-change State Change State One or more of the
LEDs on an Array has
changed state. The
following LEDs are
tracked for state
change: Alarm,
PowerA, PowerB, and
Status. The LED
values are: OFF,
SLOW_BLINK,
FAST_BLINK, or ON.
If the new value is
OFF for either
Power LED, then
check power cables.
If Status LED is
anything but ON, or
Alarm LED is
anything but OFF,
then check the
Array for alarms.
High /
Low
array-pcie-link-down Event Triggered The Array specified in
the trap has detected a
PCIe link loss.
Check the PCIe
cable between the
Array and the HP
VMA SAN
Gateway.
High
array-pcie-link-up Event Triggered The Array specified in
the trap has detected
that the PCie link has
gone active.
Nothing. Low