242 HP VMA SAN Gateway Users Guide AM456-9026A
unexpected-
shutdown
Event Triggered A HP VMA SAN
Gateway has
unexpectedly
shutdown. This may
happen during a
software upgrade when
the upgrade did not
cleanly apply and the
system reverted back
to the previous version
prior to upgrade. A
callhome event is
generated.
Please contact HP
customer support.
High
user-login Event Triggered A login to a HP VMA
SAN Gateway via
either the CLI or Web
UI has occurred.
Verify the user id
has not been
compromised.
Low
user-logout Event Triggered A logout from a HP
VMA SAN Gateway
via either the CLI or
Web UI has occurred.
Check that the
appropriate settings
for auto-logout are
configured for the
user. There are
separate settings for
the CLI vs. Web UI.
Low
vimm-state-change State Change State One or more VIMMs
have changed state on
a HP Array. A comma
separated list of
VIMMs are provided
for each state:
admin_down, booting,
active, spare, failed,
present, or alarmed.
The set value for each
VIMM list / state
change is “true” for set
or “false” for clear.
Check the HP VMA
Array for alarms to
determine severity
of state change.
High /
Low
vimm-temperature-
high
80 Celsius VIMM temperature
has exceeded normal
operating range
Check VMA array
airflow and
operating
environment.
High
vimm-temperature-
ok
75 Celsius VIMM temperature
has dropped into
normal operating range
Nothing. Low
Trap Name Threshold Value Unit Description Solution Sev.