Owner manual

AM456-9026A HP VMA SAN Gateway Users Guide 243
vmg-boot-raid-
change
NA Active,
Degraded,
Resyncing,
Unknown
There was a state
change in the book
disk. The states are as
follows:
Active is a normal
state.
Resyncing means
the RAID group is
rebuilding, which
is also normal.
Degraded means
the RAID disk is
down.
Unknown means
the RAID disk is
unavailable and
could be down.
Degraded and
Unknown status
mean that the RAID
disk is likely down
and needs to be
replaced.
High
vmg-fan-change NA Off,
Absent,
Low,
Medium,
High,
One or more fans have
changed state on a HP
VMA SAN Gateway.
An absent status
could mean a failed
fan. Replace the fan
as soon as possible.
High
vmg-psu-change NA On, Off,
Absent
Power supply status
changed. There are two
power supply units and
both should be on.
If the status changes
to off or absent,
investigate the issue
immediately.
High
Trap Name Threshold Value Unit Description Solution Sev.