HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets
Property Name
Property Implementation
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) – if power supply is operating properly;
3 (Degraded) – if power supply is degraded;
6 (Error) – if power supply has failed
OperationalStatus[1]
Extended Warning and Error status. See the MOF and Profile
StatusDescriptions[0]
Description of the status of the power supply corresponding to the
OperationalStatus.
For example:
Power Supply is operating properly– if OperationalStatus[0]
is 2 (OK);
Power Supply is degraded – if OperationalStatus[0] is 3
(Degraded)
Power Supply has failed – if OperationalStatus is 6 (Error)
StatusDescriptions[1]
Description of the extended warning/error status corresponding to the
OperationalStatus[1]. See Profile.
HealthState
5 (OK) – if power supply is operating properly;
10 (Degraded) if power supply is degraded
20 (Major Failure) – if power supply has failed
Name
Unique name of this power supply from the name displayed by the MP or
iLO and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
HP Insight Management Power Supply Provider Overview 4