HP Insight Management WBEM Providers for ESXi 5.0 SNMP Migration Guide March 2012
Table Of Contents
- 1 Introduction
- 2 Overview of the Insight Management MIB
- 3 High Level Mapping
- 4 Server MIB Variable to WBEM Property Mappings
- 5 Storage MIB Variable to WBEM Property Mappings
- 6 Network MIB Variable to WBEM Property Mappings
- 7 Server Trap to Indication Mappings
- 8 Storage Trap to Indication Mappings
- 9 Network Trap to Indication Mappings
- 10 Revisions
Trap OID Name
cpqSsTempFailed
Indication Class
SMX_SmartArrayStorageEnclosureTempIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”“HP SAS”
Indication EventID
“309”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs3TempFailed will be generated
Trap OID
1.3.6.1.4.1.232.8003
Trap OID Name
cpqSsTempDegraded
Indication Class
SMX_SmartArrayStorageEnclosureTempIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”“HP SAS”
Indication EventID
“308”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not b
e generated for this condition.
cpqSs3TempDegraded will be generated
Trap OID
1.3.6.1.4.1.232.8004
Trap OID Name
cpqSsTempOk
Indication Class
SMX_SmartArrayStorageEnclosureTempIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“307”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs3TempOK will be generated
Trap OID
1.3.6.1.4.1.232.8005
Trap OID Name
cpqSsSidePanelInPlace
Indication Class
Not implemented
Indication ProviderName
Indication EventID
Notes