HP Insight Management WBEM Providers for ESXi 5.0 SNMP Migration Guide March 2012
Table Of Contents
- 1 Introduction
- 2 Overview of the Insight Management MIB
- 3 High Level Mapping
- 4 Server MIB Variable to WBEM Property Mappings
- 5 Storage MIB Variable to WBEM Property Mappings
- 6 Network MIB Variable to WBEM Property Mappings
- 7 Server Trap to Indication Mappings
- 8 Storage Trap to Indication Mappings
- 9 Network Trap to Indication Mappings
- 10 Revisions
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs6PwrSupplyStatusChange will be generated
Trap OID
1.3.6.1.4.1.232.8018
Trap OID Name
cpqSsExPowerSupplyUpsStatusChange
Indication Class
SMX_SmartArrayStorageEnclosureIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“301”, “302”, “303”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs6PwrSupplyStatusChange will be generated
Trap OID
1.3.6.1.4.1.232.8019
Trap OID Name
cpqSsExTempSensorStatusChange
Indication Class
SMX_SmartArrayStorageEnclosureTempIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“307”, “308”, “309”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this co
ndition.
cpqSs
3TempOK, cpqSs3TempDegraded or
cpqSs3TempFailed will be generated
Trap OID
1.3.6.1.4.1.232.8020
Trap OID Name
cpqSsEx2FanStatusChange
Indication Class
SMX_SmartArrayStorageEnclosureIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“304”, “305”, “306”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs6FanStatusChange will be generated
Trap OID