HP Insight Management WBEM Providers for ESXi 5.0 U1 SNMP Migration Guide June 2012
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“308”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs3TempOK, cpqSs3TempDegraded,
cpqSs3TempFailed will be generated
Trap OID
1.3.6.1.4.1.232.8024
Trap OID Name
cpqSsExBackplanePowerSupplyStatusChange
Indication Class
SMX_SmartArrayStorageEnclosureIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“301”, “302”, “303”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs6PwrSupplyStatusChange will be generated
Trap OID
1.3.6.1.4.1.232.8025
Trap OID Name
cpqSsExRecoveryServerStatusChange
Indication Class
Not Implemented
Indication ProviderName
Indication EventID
Notes
Trap OID
1.3.6.1.4.1.232.8026
Trap OID Name
cpqSs5FanStatusChange
Indication Class
SMX_SmartArrayStorageEnclosureIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“304”, “305”, “306”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs6FanStatusChange will be generated
Trap OID
1.3.6.1.4.1.232.8027
Trap OID Name
cpqSs5TempStatusChange