HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

Version 1.1.0 9
7.3 HP_SystemPhysicalFan
There shall be one instance of HP_SystemPhysicalFan instantiated for each instance of HP_FanModule.
This class associates instances of HP_FanModule with CIM_PhysicalPackage.
7.4 HP_FanInSlot
If an instance of CIM_Slot representing the fan slot exists, there shall be one instance of HP_FanInSlot
instantiated for each instance of HP_FanModule. This class associates an instance of HP_FanModule
with a corresponding instance of CIM_Slot.
7.5 CIM_Slot.ElementName
If an instance of CIM_Slot representing the fan slot exists, CIM_Slot.ElementName shall be implemented
and shall contain a descriptive name of the fan slot and Number, in a user displayable format.
8 Methods
None.
9 Use Cases
9.1 Object Diagram
Figure 3 represents a possible instantiation of the HP Fan Physical Asset Profile. In this case, system1
has two fans, fan1 and fan2. Fan1 and fan2 are associated to fan modules fm1 and fm2 via
HP_RealizesFan. These fan modules are respectively associated to slots fanslot1 and fanslot2 via
HP_FanInSlot. The fan modules are all also associated to chassis1 via HP_SystemPhysicalFan. This
diagram also shows an example of the HP_Fan.Description property for fm1 and fm2, constructed from
property values for ElementName, FanType and value map string of OperationalStatus[0].
For simplicity most properties have been removed from the classes.