HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

Version 2.1.0 13
7.4.8 HP_BladeEnclosureCS.OperationalStatus
This property shall be supported by the operational status of the shared enclosure sub-systems. Multi-
node server chassis may populate this value with “unknown” if the multi-node server chassis does not
report status for the chassis or shared resources.
7.4.9 HP_BladeEnclosureCS.ManagementIPAddress
This property shall be supported by the populating the string representation of the enclosure’s currently
active management IP Address. Multi-node server chassis may populate this value with NULL or an
empty string if the multi-node server chassis does not report this information.
7.4.10 HP_BladeEnclosureCS.ManagementURL
This property shall be supported by the populating the string representation of the enclosure’s currently
active management home page URL. Multi-node server chassis may populate this value with NULL or an
empty string if the multi-node server chassis does not report this information.
7.4.11 HP_BladeEnclosureCS.ManagementMACAddress (Optional)
This property may be supported by providing the string representation of the Onboard Administrator’s
(Enclosure Manager) currently active MAC Address. . Multi-node server chassis may populate this value
with NULL or an empty string if the multi-node server chassis does not report this information.
7.4.12 HP_BladeEnclosureCS.RackName
This property may be supported by populating the string representation the name of the rack containing
the enclosure. . Multi-node server chassis may populate this value with NULL or an empty string if the
multi-node server chassis does not report this information.
7.4.13 HP_BladeEnclosureCS.RackUID
This property may be supported by populating the string representation of the Rack UID. . Multi-node
server chassis may populate this value with NULL or an empty string if the multi-node server chassis
does not report this information.
7.4.14 HP_BladeEnclosureCS.EnclosureName
This property may be supported by populating the name of the Enclosure. . Multi-node server chassis
may populate this value with NULL or an empty string if the multi-node server chassis does not report this
information.
7.5 HP_BladeEnclosureCollection
The blade enclosure collection instance shall follow the HP Consolidated Status profile as defined in the
section describing the HP_GroupSystemSpecificCollection class.
The algorithm used by the collection class is worst case.
Multi-node server chassis that do not report status SHALL NOT populate this class.
7.6 HP_BladeEnclosureGroupHostedCollection
The blade enclosure group hosted collection instance shall follow the HP Consolidated Status profile as
defined in the section describing the HP_GroupHostedCollection class.