HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

Version 1.3.0 13
There may be one or more instance of HP_SuppliesPower instantiated. Instances of HP_PowerSupply
are associated to CIM_ManagedSystemElement through the HP_SuppliesPower association.
7.10 HP_PowerMeter
When the power supply supports reporting power consumption or power production; there shall be an
instance of HP_PowerMeter for each installed power supply capable of reporting power consumption or
power production.
7.10.1 HP_PowerMeter.SensorType
HP_PowerMeter.SensorType property shall be implemented. This property describes the type of the
power meter supported. This property shall be either 13 (power consumption) or 14 (power production).
The sensor shall follow the mandates specified by DSP1009 Sensor Profile.
7.11 HP_AssociatedPowerMeter
When the HP_PowerMeter is instantiated, there shall be an instance of HP_AssociatedPowerMeter
associating the power meter instance to the power supply instance.
8 Methods
None.
9 Use Cases
9.1 Object Diagrams
Figure 3 represents a possible instantiation of the HP Power Supply Profile. In this case, system1 has
two power supplies, ps1 and ps2. They belong to powercollection1, which describes the overall group
operational status of the power supplies as being OK. Each of the power supplies support reporting
power meter sensor information in pm1 and pm2. The power meters are associated to the power
supplies via the HP_AssociatedPowerMeter association.
For simplicity most of the properties have been removed from the classes.