HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

SAS HBA Provider Datasheet version 1.05
The following chapters define the supported properties for the SAS HBA provider. For details of each
property, see the HP SAS HBA profile (P00122) and associated MOF file.
1-1-1 SMX_SASArraySystem
SMX_SASArraySystem represents the top level system. There is one instance per HBA.
Table 16-1 Class: SMX_SASArraySystem (CIM_ComputerSystem)
Property name
Property implementation
CIM_ManagedElement
ElementName Controller name and location
For example, HP 8 INT Port SAS/SATA HBA in Slot 3
CIM_ManagedSystemElement
OperationalStatus[0] Overall status of the Array System and attached
devices. This is calculated as per the algorithm
described in the HP SAS HBA Profile.
0 (Unknown)
2 (OK)
3 (Degraded)
6 (Error)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)
CIM_System
CreationClassName
SMX_SASArraySystem
Name
Controller Serial Number
NameFormat
Other
CIM_ComputerSystem
Dedicated
Dedicated[0]: 3 (Storage)
Dedicated[1]: 15 (Block Server)
IdentifyingDescriptions
Other Vendor Specific Name
OtherIdentifyingInfo
Controller Serial Number
1-1-2 SMX_SASArrayController