HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 392
Property Name Property Implementation
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName HP Smart Array
RecommendedActions No action is recommended.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary Physical Drive status OK
EventCategory
6 (Primary Storage)
ProbableCause
1 (Other)
ProbableCauseDescription Physical Drive Status Changed to OK
NetworkAddresses
Contains a list of all the IP addresses of the computer system
generating the indication
OSType SMX_OperatingSystem.OSType
OSVersion
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion
For example: 2.2.0.0
SystemFirmwareVersion
Firmware version of the computer system generating the
indication
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the indication
SystemModel
Model name of the computer system generating the
indication
SystemGUID
Platform GUID of the computer system generating the
indication
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
Note:
When ImpactedDomain is 3 (Enclosure) the properties that
follow and are indicated with an asterisk (*) below will be
populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name