HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 402
Property Name Property Implementation
SystemVirtualUUID
Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
HP_HardwareIndication
HWLogicalLocation
Logical drive number and RAID Level
For example:
LogicalDrive1 (RAID 1+0).
VariableNames[] FailureDescription
VariableTypes[]
String (1)
VariableValues[]
FailureDescription short description of the failure
HP_DeviceIndication
HPSA_StorageVolumeIndication
DeviceOperationalStatus
Current OperationalStatus values for Storage Volume
DeviceOperationalStatus[0]:
SMX_SAStorageVolume.OperationalStatus[0]
DeviceOperationalStatus[1]:
SMX_SAStorageVolume.OperationalStatus[1]
(This index is only populated if there is additional Vendor
unique status available)
DeviceOperationalStatusPrevious
Previous OperationalStatus values for Storage Volume
DeviceOperationalStatusPrevious[0]:
SMX_SAStorageVolume.OperationalStatus[0]
DeviceOperationalStatusPrevious[1]:
SMX_SAStorageVolume.OperationalStatus[1]
(This index is only populated if there is additional Vendor
unique status available)
SMX_SAStorageVolumeIndication: Logical Drive Status
Changed to ERROR
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description A logical drive status has changed to Error.
AlertingManagedElement
WBEM Path of SMX_SAStorageVolume class