HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet
HP Insight Management WBEM Smart Array Provider 409
Property Name Property Implementation
VariableNames[]
FailureDescription
CacheSizeTotal
CacheSerialNumber
VariableTypes[]
String (1)
uint32 (5)
VariableValues[]
FailureDescription – short description of the failure
CacheSizeTotal
HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel
Array Controller Model string
HP_DeviceIndication: Controller Status Changed to ERROR
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Smart Array controller status has changed to Error.
AlertingManagedElement
WBEM Path to SMX_SAArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 2
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array (
RecommendedActions Check controller status and run diagnostics.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary Controller status Error
EventCategory
6 (Primary Storage)
ProbableCause
24 (I/O device error)