HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets
HP Insight Management Power Supply Provider Overview 14
Property Name
Property Implementation
20 (Major Failure) – if power supply has failed
Name
Short description of this power supply for the name displayed by the MP or iLO
and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
CIM_PhysicalElement
CreationClassName
SMX_PowerSupplyModule
PartNumber
The part number assigned by the organization that is responsible for producing
or manufacturing the PhysicalElement.
SerialNumber
A manufacturer-allocated number used to identify the Physical Element.
Tag
Unique identifier for this power supply instance.
CIM_PhysicalPackage
RemovalConditions
0 (Unknown)
3 (Removable when off)
4 (Removable when on or off)
PackageType
6 (PowerSupply)
1-2-12 SMX_SystemPhysicalPowerSupply Class
The SMX_SystemPhysicalPowerSupply class extends the CIM_Container class and association of the
HP_ComputerSystemChassis instance with HP_PowerSupplyModule.
The following table lists the properties implemented.
Property Name