HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

HP Insight Management WBEM CPU Provider Overview 10
Property Name
Property Implementation
StatusDescriptions
StatusDescriptions[0]
text per
OperationalStatus[0]
:
Unknown.
OK
Predictive Failure
Error
Stopped
HealthState
0 (Unknown), when OperationalStatus[0]=0 (Unknown)
5 (OK), when OperationalStatus[0]=2 (OK)
15 (Minor Failure), when OperationalStatus[0]=10 (Stopped)
20 (Major Failure), when OperationalStatus[0]=5 (Predictive Failure)
25 (Critical Failure), when OperationalStatus[0]=6 (Error)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledState
2 (Enabled)
RequestedState
12 (Not Applicable)
EnabledDefault
2 (Enabled)
CIM_ProcessorCore
InstanceID
HPQ:SMX_ProcessorCore Proc:<p> Core:<c>
Where: <p> is the processor number and <c> is the core number.
CoreEnabledState
2
(Core Enabled)