HP VMware vSphere 5.1 U1 OS Customized Image Release Notes for April 2013

4 Important notes and recommendations
The drivers and firmware recipe information for HP ProLiant servers and options can be found at
the following link: http://vibsdepot.hp.com/hpq/recipes.
AMS and Active Health Installation
AMS and Active Health is shipped as part of the HP Custom Image, the HP ESXi Offline Bundle
and the new Agentless Management Service Offline Bundle. The HP Custom Image and the HP
ESXi Offline Bundle also include the HP Insight Management WBEM Providers. The AMS Offline
Bundle only includes the providers required to support online firmware update and SmartArray,
DIMM Status and iLO reporting in vCenter. Customers can manage their ProLiant servers using
Agentless Management without installing the AMS Offline Bundle. Only customers who intend to
manage their ProLiant servers using only Agentless Management and do not need the full set of
HP Insight Management WBEM Providers installed should install the AMS Offline Bundle. See the
Deploying and updating vSphere 5.0 on Proliant servers white paper for more information.
If the customer has vSphere 5.1 U1 and is currently using HP Insight Management WBEM Providers
for ESXi and requires Agentless Management and does not need the full set of providers installed,
they need to perform the following step:
Install the AMS Offline Bundle to replace the HP ESXi Offline Bundle
If the customer has vSphere 5.1 U1 and is currently using Agentless Management and does not
have the full providers installed and wants to move to using HP Insight Management WBEM
Providers for vSphere, they need to perform the following step:
Install the HP vSphere Offline Bundle to replace the AMS Offline Bundle.
System Memory required for installing vSphere 5.1 U1 Customized Image
VMware vSphere will not install on an HP Gen8 server with 2 GB or less system memory. Although
VMware’s stated minimum installation requirement is 2 GB of system memory, HP’s Gen8 platforms
do not expose enough of the 2 GB of system memory to the operating system, causing the installation
to fail. This issue is resolved by populating the system with more than 2 GB of memory.
HP Dynamic Smart Array Controllers cannot be used as the target for a core dump (B120i with PCI
ID 8086 1C04 1590 006C)
SAS WWIDs for b120i controllers will be non-unique
7