Installation and Reference Guide for HP MPIO Full Featured DSM for MSA1000/1500 (Active-Active) Disk Arrays 3.00.00 (AA-RW8AD-TE, March 2008)

hpdsm paths device=1
Path# Controller Port
#
State
HBA Slot#
RTP P.B.T.L
1
P56350FX3Q5006-1 Available
4
00010001 3.1.3.1
2 P56350GX3RI0F6-1 Available
4
00020002 4.1.3.1
hpdsm set device policy
Syntax: hpdsm set device=x policy=policy
Syntax: hpdsm set device=all policy=policy
The hpdsm set device policy command sets the load balancing policy for device x or all
devices, depending on the input parameter specied, to one of the following:
No_Load_Balance (NLB)
Round_Robin (RR)
Shortest_Queue_Requests (SQR)
Shortest_Queue_Bytes (SQB)
Shortest_Queue_ServiceTime (SQST)
The example below demonstrates the information displayed by the hpdsm set device policy
command.
NOTE:
You can not change the load balance policy in an MSCS/Failover Cluster environment.
Example:
hpdsm set device=1 policy=sqst
Device Name
: HP MSA_VOLUME
Device Serial No. : 600508B300912160AF87D3596705001B
Change Load Balance policy (y/n)? y
Load Balance policy changed. Verify by issuing "hpdsm devices" command.
Example:
hpdsm set device=all policy=rr
Successful for all the devices. Verify by issuing "hpdsm devices" command.
hpdsm set device path
Syntax: hpdsm set device=x path=y
The hpdsm set device path command changes the preferred path for device x,asshowninthe
example below.
NOTE:
Use the hpdsm paths device command to view the available paths for the device.
HP MPIO Full Featured DSM for MSA1000/1500 (Active-Active) Disk Arrays 3.00.00
23