HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Overview 1. 2. 3. 4. HP ProLiant WS460c G6 Workstation Blade Two (2) mezzanine I/O expansion slots 5. Two (2) small form factor (SFF) hot-plug drive bays Internal USB connector 6. Local I/O Connector Twelve (12) DDR3 Registered or Unbuffered DIMM Memory 7. Internal SD card slot Slots 8. Up to two (2) Intel® Xeon® 5500 series processors HP Smart Array P410i Controller 9.
QuickSpecs HP ProLiant WS460c Generation 6 (G6) Workstation Blade Overview Up to 24GB, using PC3-10600 DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fully populated at 2 DIMMs per Channel in 12 slot Storage Controller: HP Smart Array P410i Controller (RAID 0/1) with optional 256MB or 512MB Battery-Backed Write Cache (BBWC) Internal Drive Support: Up to two (2) small form factor (SFF) SAS hot plug hard disk drives Network Controller: Embedded NC532i Dual Port Flex-10 10GbE Multifunction Server
QuickSpecs HP ProLiant WS460c Generation 6 (G6) Workstation Blade Overview management console. NOTE: ICE-Linux is not supported in the WS460c G6. Operating Systems: Supports following: (Not preinstalled or preloaded) Genuine Microsoft® Windows Vista® Business (32-bit and 64-bit) Genuine Microsoft® Windows® XP Professional 32-bit SP3 Genuine Microsoft® Windows® XP Professional x64 Edition with SP2 RedHat Enterprise Linux version 4.8 or 5.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Standard Features Processor Quad-Core Processors Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) Intel® Xeon® Processor E5530 (2.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Standard Features Memory Type DDR3 Registered (RDIMM) Standard 2GB (2 x 1GB) UDIMM 4GB (4 x 1GB) UDIMM Maximum (RDIMM) 96GB (12 x 8 GB) for Registered Memory configurations Maximum (UDIMM) 24 GB (12 x 2 GB) for Unbuffered Memory configurations NOTE: Depending on the memory configuration and processor model the memory speed may run at 1333MHz, 1066MHz or 800MHz. Please see the Online Memory Configuration Tool for details: www.hp.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Standard Features Number of displays Up to two displays Graphics driver Single, unified driver compatible with FX 770M and FX 3600M Integrated Manageability ProLiant Onboard Administrator (powered by the Integrated Lights-Out 2 management processor) Storage Controller Type HP Smart Array P410i Controller (RAID 0/1) Available Options: 256MB cache, Battery-Backed Write Cache (BBWC) module for 256MB cache, 512MB cache with Battery Backe
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Standard Features Compatible SAN HP ProLiant WS460c G6 workstation blades are optimized for HP StorageWorks MSA, EVA and XP. HP ProLiant 460c G6 server blades are compatible with select 3rd party SANs (please see blade storage page for more details: http://h18000.www1.hp.com/products/servers/proliant-bl/cclass/storage.html NOTE: HP ProLiant WS460c G6 does not support boot from SAN.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Standard Features Factory Express Portfolio HP Factory Express offers configuration, customization, integration and deployment services for HP servers for Servers and Storageand storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Models FX 770M graphics preconfigured models HP WS460c G6 E5540Processor(s) 4GB (1P) Dual FX770MOne of the following (quad display) depending on model 580641-B21 (1) Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) (1) Intel® Xeon® Processor E5530 (2.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Configuration Information - Factory Integrated Models NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO product offerings and requirements. NOTE: HP does not allow factory integration of options into standard models listed above.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Configuration Information - Factory Integrated Models Intel® Xeon® processor HP L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800) BL460c G6 Kit, FIO NOTE: If two processors are desired, select one 513859-L21 and one 513859-B21. 513859-L21 Intel® Xeon® processor HP E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) BL460c G6 Kit, FIO NOTE: If two processors are desired, select one 507800-L21 and one 507800-B21.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Configuration Information - Factory Integrated Models Step 4: Choose Additional Options for Factory Integration NOTE: For additional options, please refer to the "Core Options" and "Additional Options" section below.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Core Options HP Processors Quad-Core Process Option Kits Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) BL460c G6 Kit 507791-B21 Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) BL460c G6 Kit 507792-B21 Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) BL460c G6 Kit 507793-B21 Intel® Xeon® Processor E5540 (2.
QuickSpecs HP ProLiant WS460c Generation 6 (G6) Workstation Blade Core Options HP Hard Drives SAS Hot Plug SFF (2.5-inch) Enterprise (ENT) Drives HP 300GB 3G SAS 10K SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive 492620-B21 HP 146GB 3G SAS 15K SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive 504062-B21 HP 146GB 3G SAS 10K SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive 418367-B21 HP 72GB 3G SAS 15K SFF (2.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Additional Options HP Remote Access HP Remote Graphics Software (RGS) v5.3.0 NOTE: HP RGS is a licensed software sold separately. Not bundled with HP WS460c G6. NOTE: For remote access to Windows Vista OS on blade, HP RGS version 5.3 or later is required. NOTE: For more information on HP Remote Graphics Software, please find HP Remote Graphics in: http://www.hp.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Additional Options HP StorageWorks SB40c HP StorageWorks SB40c Storage Blade Storage Blade NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12587_div/12587_div.html (Worldwide) 411243-B21 HP Expansion Blade 448018-B21 HP PCI Expansion Blade NOTE: Ships with one pre-installed PCI-X connect board.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Memory NOTE: Memory configurations listed do not apply to "Factory Integrated Models". Memory Population Guidelines For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Memory 95 Watt CPU's are required for 1333MHz DIMM speeds References to the above MHz speeds are for the various speeds of DDR3 DIMMs; 1333 refers to DDR3-1333, etc. HP ProLiant WS460c G6 Workstation Blade DIMM slot and configuration diagrams Basic memory slot and population diagram Population order; start with "A" first, "B" second, "C" third, etc.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Memory slot # Chnl 1 1 2 CPU1 population order D: 1GB DIMM (if 4GB model), 2GB DIMM (if 2GB model) A: 1GB DIMM slot # CPU2 population order Chnl 1 1 D: empty 2 A: empty Chnl 2 3 4 E: 2GB DIMM B: 1GB DIMM 3 4 E: empty B: empty Chnl 2 Chnl 3 5 F: 2GB DIMM C: 1GB DIMM (if 4GB model), 2GB DIMM (if 2GB model) 5 F: empty Chnl 3 6 C: empty 6 UDIMM maximum configuration (1 CPU model); Standard Memory Replaced with Optional Me
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Memory UDIMM maximum configuration (2 CPU model) 24GB, consisting of twelve (12) 2GB dual-rank PC3-10600 UDIMMs slot # 1 2 Chnl 1 CPU1 population order D: 2GB DIMM A: 2GB DIMM slot # 1 2 CPU2 population order D: 2GB DIMM A: 2GB DIMM Chnl 1 Chnl 2 3 4 E: 2GB DIMM B: 2GB DIMM 3 4 E: 2GB DIMM B: 2GB DIMM Chnl 2 Chnl 3 5 6 F: 2GB DIMM C: 2GB DIMM 5 6 F: 2GB DIMM C: 2GB DIMM Chnl 3 NOTE: Capacity references are rounded to the c
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Storage 1-2 2 x SFF SAS Hot Plug Hard Drives Hard Drives NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components. SAS Hot Plug SFF (2.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Technical Specifications System Unit Dimensions (H x W x D) 7.154 x 2.19 x 20.058 in (18.17 x 5.56 x 50.95 cm) (with bezel) Weight (approximate) Power Specifications Maximum (all hard drives and processors installed) 14.20 lb (6.44 kg) Minimum (one hard drive and processor installed) 10.75 lb (4.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Technical Specifications http://h18000.www1.hp.com/products/quickspecs/12790_div/ 12790_div.html HP BladeSystem c7000 Enclosure QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/12810_div/ 12810_div.html HP Smart Array P410i Disk Drive Interface Controller 3Gb (6Gb Capable) SAS (Serial Attached SCSI) 1.
HP ProLiant WS460c Generation 6 (G6) Workstation Blade QuickSpecs Technical Specifications Environment-friendly End-of-life ManagementHewlett-Packard offers end-of-life HP product return, trade-in, and recycling Products and Approach and Recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office.