Table 7 RAID Manager Error Codes (continued)
DescriptionSSB2 code
The volume you specified as a P-VOL was a Cnt Ac-S S-VOL. The Split operation was rejected because
the consistency time of the consistency group is not equal to the consistency time of the Cnt Ac-S pair.
2094
The Quick Restore operation was rejected because of one of the following:2097
The P-VOL was also a Thin Provisioning V-VOL, but the S-VOL was a normal volume.
The P-VOL was a normal volume, but the S-VOL also a Thin Provisioning V-VOL.
The Quick Restore operation was rejected because the emulation type of only one of the volumes in
the pair was OPEN-0V.
209B
The Quick Restore operation was rejected because the updated information about storage system
configuration was being backed up.
209C
The pair operation was rejected because the volume you specified as the P-VOL was a Mainframe
Fibre Data Migration volume.
209E
The pairs you specified contain the Cnt Ac-S asynchronous volumes. The Quick Restore operation was
rejected because the CLPRs of the P-VOL and S-VOL for the pair you specified were different.
20A0
The create pair operation was rejected because the P-VOL was a Thin Provisioning or Smart Tiers
V-VOL whose capacity was increasing.
20A2
The create pair operation was rejected because the S-VOL was a Thin Provisioning or Smart Tiers
V-VOL whose capacity was increasing.
20A3
The pair operation was rejected because the consistency group number you specified was being used
by FS or SS.
20A9
The pair operation was rejected because the volume you specified as the P-VOL was a Thin Provisioning
or Smart Tiers V-VOL and its zero pages were being reclaimed.
20AA
The pair operation was rejected because the volume you specified as the S-VOL was a Thin Provisioning
or Smart Tiers V-VOL and its zero pages were being reclaimed.
20AB
The pair operation was rejected because the volume you specified as the P-VOL was a Thin Provisioning
or Smart Tiers V-VOL and its capacity was increasing.
20B0
The pair operation was rejected because the volume you specified as the S-VOL was a Thin Provisioning
or Smart Tiers V-VOL and its capacity was increasing.
20B1
The pair operation was rejected because the volume you specified as the P-VOL was a Thin Provisioning
or Smart Tiers V-VOL, which was not associated with a pool.
20B4
The pair operation was rejected because the volume you specified as the S-VOL was a Thin Provisioning
or Smart Tiers V-VOL, which was not associated with a pool.
20B5
The pair operation was rejected because you did not define an LU path to the volume you specified
as the P-VOL.
20B7
The pair operation was rejected because you did not define an LU path to the volume you specified
as S-VOL.
20B8
The pair operation was rejected because the emulation type of the volume you specified as the P-VOL
is 3390-V.
20BD
The pair operation was rejected because the emulation type of the volume you specified as the S-VOL
is 3390-V.
20BE
The emulation type of the P-VOL was 3390-A, and the pair operation was rejected for one of the
following reasons:
20C9
Mainframe Fibre CHA was not mounted
Mainframe Fibre CHA was all blocked