Pair 1 is a Cnt Ac-S pair.
Pair 2 is a Cnt Ac-J pair.
Pair 3 is a Cnt Ac-J pair for delta resync.
Pairs 4, pair 5, and pair 6 are FS pairs.
1. Create 3DC multi-target and delta resync pairs (pairs 1, 2, and 3).
2. Create pair 4.
3. Create pairs 5 and 6.
Thin Provisioning
Note the following if you are using FS, THP, and Thin Provisioning Z (THP Z) in a single storage
system:
If you are expanding the THP V-VOL capacity, you cannot create FS pairs that have an THP
V-VOL as the P-VOL.
You can use a maximum volume size of 4 TB (4,398,046,511,104 bytes) THP volume as a
FS P-VOL.
If you specify TB, GB, or MB as the unit when creating a volume, you cannot create a volume
of 4 TB (4,398,046,511,104 bytes). To create a volume of 4 TB (4,398,046,511,104 bytes),
for unit, specify block.
The following table explains how the maximum LDEV capacity differs depending on the
specified unit.
Maximum LDEV capacityUnit specification
3.99TB
4,095.99GB
4,194,303.75MB
8,589,934,592block