User guide

For details about error codes that are not described in the following table, contact HP Technical
Support.
The following table shows the RAID Manager error codes for SSB1: 2E31, B901, B9A8, B9A9,
B9AD, B9AE).
Cause of errorRAID Manager commandSSB2
You cannot run the command because the user authentication is not performed.All commands9100
You cannot create the FS or SS pair because of a shortage of pair tables.paircreate9685
You cannot create the FS or SS pair because the pool is not available.paircreate9700
You cannot create the FS or SS pair because you specified a pool ID different
from the pool ID used by existing pairs with the specified P-VOL.
paircreate9702
You cannot create the FS or SS pair because the volume you specified as the
P-VOL is already used by another FS or SS S-VOL.
paircreate9703
You cannot create the FS or SS pair because the volume you specified as the
S-VOL is already used by another FS or SS P-VOL.
paircreate9704
You cannot create the FS or SS pair because the volume you specified as the
S-VOL is already used by another FS or SS S-VOL.
paircreate9705
You cannot create the FS or SS pair because the specified snapshot ID is already
used by another FS or SS pair.
paircreate9706
You cannot create the FS or SS pair because the capacity of the pair that you
are trying to create exceeds the licensed capacity.
paircreate9707
The command ended abnormally. You tried to use a command other than
paircreate for the volume in the pair other than the FS or SS pair.
All commands9718
This error also can occur if you run the command specifying an unsupported
parameter.
The command ended abnormally because the pair is in a status that the command
does not accept.
All commands9719
This error also can occur if you run the command specifying an unsupported
parameter.
You cannot create the FS or SS pair because the capacity of shared memory is
insufficient.
paircreate971A
You cannot restore the FS or SS pair because the volume you specified as the
P-VOL has an S-VOL Disable attribute.
pairresync -restore971F
An error occurred for one of the following reasons:All commands9720
The LDEV number that is specified for the P-VOL or S-VOL is not correct.
The specified P-VOL or S-VOL has not been paired.
The pair that is specified by the P-VOL or S-VOL is not ready for the specified
task.
The specified snapshot identifier (MU number) is not correct.
The specified snapshot identifier (MU number) is already in use.
The specified pool is unusable.
The license capacity is exceeded.
Control tables for FS or SS are running out.
The command ended abnormally because you have not installed SS or BC.paircreate, pairsplit,
pairresync, pairresync -
restore
9721
The command ended abnormally because there is no additional shared memory
(FC Z, TPF, Extension1).
All commands9723
74 RAID Manager command reference