USER’S GUIDE Integrated RAID July 2003 Version 1.
This document is preliminary. As such, it contains data derived from functional simulations and performance estimates. LSI Logic has not verified either the functional descriptions, or the electrical and mechanical specifications using production parts. This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used by or disclosed to third parties without the express written permission of an officer of LSI Logic Corporation.
Preface This user’s guide explains how to configure and use the components of the LSI Logic Integrated RAID (IR) software product. Audience This user’s guide assumes that you have some familiarity with installing and configuring software programs and that you are familiar with computer storage devices in general.
• Chapter 5, Setting Up Integrated Striping, describes how to set up Integrated Striping (IS) using the BIOS-based configuration utility. • Chapter 6, CIM Solution, describes the Fusion-MPT™ Common Information Model (CIM) Solution and explains how it is used to monitor storage components, including mirrored and striped volumes, in multiple systems on a network.
Contents Chapter 1 Introduction to Integrated RAID 1.1 Introduction 1.2 Integrated RAID Benefits and Features 1.3 Using this Manual Chapter 2 Integrated Mirroring (IM) Overview 2.1 Introduction 2.2 Features 2.3 Description 2.4 Integrated Mirroring Firmware 2.4.1 Host Interface 2.4.2 Resynchronization with Concurrent Host I/O Operation 2.4.3 Meta Data Support 2.4.4 Hot Swap 2.4.5 SMART Support 2.4.6 Floating Hot Spare 2.4.7 Media Verification 2.4.8 SCSI ID Assignment 2.4.9 Disk Write Caching 2.4.
Chapter 3 Setting Up Integrated Mirroring 3.1 IM Configuration Overview 3.2 Configuring IM with the BIOS-Based CU 3.2.1 Quick IM Configuration Procedure 3.2.2 Configuration Screen Overview 3.2.3 Detailed IM Configuration Procedure 3.2.4 Other BIOS-Based CU Screens 3.3 Troubleshooting 3.3.1 RAID Properties Menu Item Disabled 3.3.2 IM Volume Uses Extra SCSI ID 3.3.3 Configuration Utility Disables Selection of Disk Chapter 4 Integrated Striping (IS) Overview 4.1 Introduction 4.2 IS Features 4.
5.3.1 5.3.2 RAID Properties Menu Item Disabled Configuration Utility Disables Selection of Disk 5-11 5-12 Chapter 6 CIM Solution 6.1 6.2 6.3 6.4 Description 6.1.1 Features 6.1.2 Installation and System Requirements CIM Browser Window Description 6.2.1 Connect Menu Options 6.2.2 Hardware Device Tree Options CIM Installation Instructions for Windows 6.3.1 Installing the CIM Solution 6.3.2 Uninstalling the CIM Solution CIM Installation Instructions for Linux 6.4.1 Installing the CIM Solution 6.4.
viii Contents Version 1.0 Copyright © 2003 by LSI Logic Corporation. All rights reserved.
Figures 2.1 2.2 2.3 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 4.1 4.2 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 6.
x Version 1.0 Copyright © 2003 by LSI Logic Corporation. All rights reserved.
Tables 6.1 6.2 Connect Menu Option Description Device Tree Description 6-4 6-7 xi Version 1.0 Copyright © 2003 by LSI Logic Corporation. All rights reserved.
xii Version 1.0 Copyright © 2003 by LSI Logic Corporation. All rights reserved.
Chapter 1 Introduction to Integrated RAID This chapter provides an overview of Integrated RAID, its features, and its benefits. The chapter includes these sections: • Section 1.1, “Introduction,” page 1-1 • Section 1.2, “Integrated RAID Benefits and Features,” page 1-2 • Section 1.3, “Using this Manual,” page 1-2 1.
1.
Chapter 2 Integrated Mirroring (IM) Overview This chapter provides an overview of the LSI Logic Integrated Mirroring (IM) feature and includes these sections: • Section 2.1, “Introduction,” page 2-1 • Section 2.2, “Features,” page 2-2 • Section 2.3, “Description,” page 2-3 • Section 2.4, “Integrated Mirroring Firmware,” page 2-5 • Section 2.5, “Fusion-MPT Support,” page 2-8 2.
The IM feature uses the same device drivers as the standard FusionMPT based controllers, providing seamless and transparent fault tolerance. This eliminates the need for complex backup software or expensive RAID hardware. The IM feature operates independently from the operating system, in order to conserve system resources. The BIOSbased configuration utility makes it easy to configure a mirrored volume.
• Automatic background resynchronization while host I/Os continue • Media verification 2.3 Description The LSI Logic Integrated Mirroring (IM) feature provides mirroring for the boot volume, as shown in Figure 2.1. This is accomplished through the firmware of an LSI Logic controller that supports the standard FusionMPT interface. The runtime mirroring of the boot disk is transparent to the BIOS, drivers, and operating system.
Figure 2.2 Integrated Mirroring with Two Disks Logical View Physical View LBA 1 LBA 1 LBA 1’ LBA 2 LBA 2 LBA 2’ LBA 3 LBA 3 LBA N LBA N + LBA 3’ LBA N’ Mirroring can also be configured with up to 6 mirrored disks, or 5 mirrored disks and a hot spare. Figure 2.3 shows the logical view and physical view of the mirroring configuration with more than two disks in the mirrored volume. Each “mirrored stripe” is written to a disk and is mirrored to an “adjacent” disk.
environment. (A DOS-based configuration utility is also provided for manufacturing use only.) 2.4 Integrated Mirroring Firmware This section describes features of the LSI Logic Integrated Mirroring (IM) firmware. 2.4.1 Host Interface The IM host interface uses the “Message Passing Interface” as described in the Fusion-MPT specification, including Integrated Mirroring of SCSI host adapters. Through the Fusion-MPT interface, the host OS has access to the logical IM drive as well as the physical disks.
2.4.4 Hot Swap The IM firmware supports hot swapping. The hot-swapped disk is automatically resynchronized in the background, without any host or user intervention. The hot-swapped disk must be at the same physical SCSI ID as one of the physical disks configured in the IM volume. The firmware detects “Hot Swap” removal and disk insertion. Following a “hot swap” event, the firmware readies the new physical disk by spinning it up and verifying that it has enough capacity for the IM volume.
2.4.7 Media Verification The IM firmware supports a background media verification feature that runs once per minute when the IM volume is in optimal mode. The media verification feature issues a SCSI Verify command to a segment of the disk. If the command fails for any reason, the other disk’s data for this segment is read and written to the failing disk in an attempt to refresh the data.
2.5 Fusion-MPT Support The LSI Logic Fusion-MPT architecture provides the interface to the SCSI chip/firmware to allow Integrated Mirroring. 2.5.1 BIOS ROM The BIOS uses the Fusion-MPT interface to communicate to the SCSI chip/firmware to allow Integrated Mirroring. This includes reading the Fusion-MPT configuration to gain access to the SCSI parameters that are used to define behavior between the adapter and its devices. 2.5.
Chapter 3 Setting Up Integrated Mirroring This chapter describes how to set up Integrated Mirroring (IM) using the BIOS-based configuration utility (CU). The chapter includes these topics: • Section 3.1, “IM Configuration Overview” • Section 3.2, “Configuring IM with the BIOS-Based CU” • Section 3.3, “Troubleshooting,” page 3-14 3.1 IM Configuration Overview The following constraints were made in order to simplify the IM configuration.
3.2 Configuring IM with the BIOS-Based CU The BIOS-based configuration utility (CU) is part of the Fusion-MPT BIOS. When the BIOS loads during boot and you see the message about the LSI Logic Configuration Utility, press Ctrl-c to start the utility. After you do this, the message changes to: “Please wait, invoking LSI Logic Configuration Utility...” 3.2.1 Quick IM Configuration Procedure Follow the steps below to configure an Integrated Mirroring (IM) volume with the BIOS-based CU.
d. Use the arrow keys to select the secondary (mirrored) disk for the IM volume. Select Yes as the value for the Array Disk column. If partitions are defined on this disk, a message warns you that data on the disk will be lost when the mirrored volume is created. Press Delete to confirm erasing data from the disk, or press any other key to deselect the disk. Continue with step 7. 6. To configure a mirrored volume with three to six disks, or three to five disks with an optional hot spare disk: a.
3.2.2 Configuration Screen Overview All of the BIOS-based CU screens are partitioned into the areas shown in Figure 3.1. Figure 3.1 Screen Field Definitions Header Area Menu Area Main Area Footer Area 3-4 • Header Area: Shows the product title and version. • Menu Area: Shows the currently defined menu, if any. Press F2 to move to the menu area. Select a menu item by moving the cursor to it with the right and left arrow keys and then pressing Enter.
3.2.3 Detailed IM Configuration Procedure This section provides more detail on the BIOS-based CU screens that are used to configure an IM volume. See Section 3.2.4, “Other BIOSBased CU Screens,” page 3-11 for descriptions of the other BIOS-based CU screens that are not used for this task. Note: Your system may have a different version of the FusionMPT BIOS. Therefore, the screens that you see may be slightly different from the examples shown here. 3.2.3.1 Main Screen Figure 3.
To configure an IM volume, use the arrow keys to select an adapter, and press Enter to go to the Adapter Properties screen. Note: You can also access the Global Properties screen and the Boot Adapter List screen by selecting the options in the menu area. (These screens are not used to define an IM volume.) For more information about them, see Section 3.2.4, “Other BIOS-Based CU Screens,” page 3-11. 3.2.3.
On the Adapter Properties screen, use the arrow keys to select RAID Properties and then press Enter to go to the RAID Properties screen, which is shown in Figure 3.4. After an IM volume is configured, you can select Synchronize Whole Mirror on the Adapter Properties screen to force a resynchronization of all blocks in the IM volume. The default is to resynchronize only the blocks that are out of sync in the volume, as indicated by log entries. 3.2.3.3 RAID Properties Screen Figure 3.
Configuring a two-disk mirrored volume – Use the arrow keys to select the primary disk for the IM volume (the disk with the data you want to mirror). Use the arrow keys to move to the Array Disk column for this disk, and use the + and - keys to select Yes as the value. When the “Keep Data/Erase Data” message appears, press F3 to keep the data that is currently on this disk. The value in the Array Disk column changes to Primary. Use the arrow keys to select the secondary (mirrored) disk for the IM volume.
(Optional) Use the arrow keys to select a hot spare disk for the IM volume. Select Yes as the value for the Hot Spare column. Press Esc and select Save changes, then exit this menu. (If you do not want to create the IM volume, select Discard changes, then exit this menu.) The IM volume is created when you save the changes, and synchronization of the mirrored disk(s) starts immediately.
Figure 3.5 RAID Properties Screen: One IM Volume Configured LSI Logic MPT SCSI Setup Utility Version MPTBIOS-IME-X.XX.
• Select to make this IM volume the active array (volume) on the system. Activating an array deactivates all other arrays on the Fusion-MPT controller. 3.2.4 Other BIOS-Based CU Screens The BIOS-based CU screens described in this section are not directly used to configure an IM volume. 3.2.4.1 Global Properties Screen You use the Global Properties screen to modify global properties, such as the boot information display mode, and to restore default settings.
3.2.4.2 Boot Adapter List Screen The Boot Adapter List screen is invoked by selecting Boot Adapter List from the top-level screen shown in Figure 3.2. Only devices connected to one of the SCSI boot adapters can be used to boot. Figure 3.7 shows the Boot Adapter List screen. Figure 3.7 Boot Adapter List Screen LSI Logic MPT SCSI Setup Utility Version MPTBIOS-IME-X.XX.
To remove an adapter from the top list, use the up and down arrows to select the adapter. Then press the Delete key. Press the Esc key to exit this screen. 3.2.4.3 Device Properties Screen As shown in Figure 3.8, the Device Properties screen displays virtual, as well as physical, device identifiers for disks that are part of an IM volume. (“LSILOGIC1030 IM1000” is a virtual identifier, “Seagate xxxxxxxxx” is a physical identifier.) Figure 3.
3.3 Troubleshooting The following sections provide some suggestions for troubleshooting. 3.3.
4. Save the configuration by pressing Esc and following the on-screen instructions. This creates the IM volume and triggers an automatic resync. 3.3.3 Configuration Utility Disables Selection of Disk Problem: The configuration utility does not allow a disk to be selected for an IM volume. Solution: To determine why the disk cannot be selected, press F4 on the RAID Properties screen to display diagnostic codes for each disk under the Size column.
3-16 Setting Up Integrated Mirroring Version 1.0 Copyright © 2003 by LSI Logic Corporation. All rights reserved.
Chapter 4 Integrated Striping (IS) Overview This chapter provides an overview of the LSI Logic Integrated Striping (IS) feature. It includes these sections: • Section 4.1, “Introduction” • Section 4.2, “IS Features” • Section 4.3, “IS Description” • Section 4.4, “Integrated Striping Firmware” • Section 4.5, “Fusion-MPT Support,” page 4-5 4.
4.
Figure 4.1 Integrated Striping Example LSI Logic Fusion-MPT Controller SCSI Bus Disk 1 Disk 2 Disk 3 Disk 4 Segment 1 Segment 5 Segment 9 Segment 2 Segment 6 Segment 10 Segment 3 Segment 7 Segment 11 Segment 4 Segment 8 Segment 12 Figure 4.2 shows a logical view and a physical view of integrated striping configuration. Figure 4.
4.4 Integrated Striping Firmware This section describes features of the LSI Logic Integrated Striping (IS) firmware. 4.4.1 Host Interface The IS host interface uses the “Message Passing Interface,” as described in the Fusion-MPT specification, including Integrated Striping. Through the Fusion-MPT interface, the host operating system has access to the logical IS drive as well as the physical disks. This allows support for domain validation and Ultra320 SCSI expander configuration. 4.4.
4.4.5 Disk Write Caching Disk write caching is enabled in IS volumes. 4.5 Fusion-MPT Support The LSI Logic Fusion-MPT architecture provides the interface to the SCSI chip/firmware to allow Integrated Striping. 4.5.1 BIOS ROM The BIOS uses the Fusion-MPT interface to communicate to the SCSI chip/firmware to allow Integrated Striping. This includes reading the Fusion-MPT configuration to gain access to the SCSI parameters that are used to define behavior between the adapter and its devices. 4.5.
4-6 Integrated Striping (IS) Overview Version 1.0 Copyright © 2003 by LSI Logic Corporation. All rights reserved.
Chapter 5 Setting Up Integrated Striping This chapter describes how to set up Integrated Striping (IS) using the BIOS-based configuration utility (CU). The chapter includes these topics: • Section 5.1, “IS Configuration Overview” • Section 5.2, “Configuring IS with the BIOS-Based CU” • Section 5.3, “Troubleshooting,” page 5-11 5.1 IS Configuration Overview The following restrictions were made in order to simplify the IS configuration.
• The supported stripe size is 64 Kbytes. 5.2 Configuring IS with the BIOS-Based CU The BIOS-based configuration utility (CU) is part of the Fusion-MPT BIOS. When the BIOS loads during boot and you see the message about the LSI Logic Configuration Utility, press Ctrl-c to start the utility. After you do this, the message changes to: “Please wait, invoking LSI Logic Configuration Utility...” 5.2.
If partitions are defined on the selected disks, a message appears warning you that data on the disk will be lost when the striped volume is created. You can then deselect that disk, if desired, or erase the disk and continue. 7. When you have selected all disks for the IS volume, press Esc and select Save changes, then exit this menu. (If you do not want to create the volume, select Discard changes, then exit this menu.) The IS volume exists as soon as you save the changes.
• Footer Area: Lists the valid keys that invoke actions. Items that allow you to change their value have square brackets enclosing the value. Items that allow you to “execute an action” are enclosed by angle brackets. 5.2.3 Detailed IS Configuration Procedure This section provides more detail on the BIOS-based CU screens that are used to configure an IS volume. See Section 5.2.4, “Other BIOSBased CU Screens,” page 5-9 for descriptions of the other BIOS-based CU screens that are not used for this task.
Failed, Inactive, Disabled, Degraded, or No value. No value, indicated by a dash, means there is no IS volume on this adapter. To configure an IS volume, use the arrow keys to select an adapter, and press Enter to go to the Adapter Properties screen. Note: You can also access the Global Properties screen and the Boot Adapter List screen by selecting the options in the menu area. These screens are not used to define an IS volume. For more information about them, see Section 5.2.
On the Adapter Properties screen, use the arrows to select RAID Properties and then press Enter to go to the RAID Properties screen, which is shown in Figure 5.4. 5.2.3.3 RAID Properties Screen Figure 5.4 shows the RAID Properties screen before an IS volume is configured. Figure 5.4 RAID Properties Screen: No IS Volume Configured LSI Logic MPT SCSI Setup Utility Version MPTBIOS-IS-X.XX.
Repeat the previous step to select up to five more disks for the IS volume. If partitions are defined on these disks, a message appears warning you that data on the disk will be lost when the striped volume is created. You can then deselect that disk, if desired, or continue and delete the data. When you have selected all disks for the IS volume, press the Esc key and select Save changes, then exit this menu. (If you do not want to create the IS volume, select Discard changes, then exit this menu instead.
Figure 5.5 RAID Properties Screen: One IS Volume Configured LSI Logic MPT SCSI Setup Utility Version MPTBIOS-IS-X.XX.
5.2.4 Other BIOS-Based CU Screens These BIOS-based CU screens are not directly used to configure an IS volume. 5.2.4.1 Global Properties Screen You use the Global Properties screen to modify global properties, such as the boot information display mode, and to restore default settings. This screen is invoked by selecting Global Properties from the Main screen (Figure 5.2). Figure 5.6 shows the Global Properties screen. Figure 5.
Figure 5.7 Boot Adapter List Screen LSI Logic MPT SCSI Setup Utility Version MPTBIOS-IS-X.XX.XX Boot Adapter List Delete=Remove an adapter Insert=Add an adapter Adapter PCI Bus Dev/ Func Boot Order Current Status Next Boot LSI1030 0 48 [0] On [On] Hit Insert to select an adapter from this list LSI1030 Esc=Abort/Exit 0 50 Arrow Keys=Select Item -/+ = Change [Item] Home/End=Select Item Enter=Execute - The Boot Adapter List screen shows up to four boot adapters in the top list.
5.2.4.3 Device Properties Screen As shown in Figure 5.8, the Device Properties screen displays virtual, as well as physical, device identifiers for disks that are part of an IS volume. (“LSILOGIC1030 IS” is a virtual identifier, “Seagate xxxxxxxxx” is a physical identifier.) Figure 5.8 Device Properties Screen LSI Logic MPT SCSI Setup Utility Version MPTBIOS-IS-X.XX.
• Is an IS volume already created on each Fusion-MPT adapter in the system? • Is “Disable Integrated RAID” set to Yes in the Global Properties screen? • Are there at least two disks on the selected SCSI bus? 5.3.2 Configuration Utility Disables Selection of Disk Problem: The configuration utility does not allow a disk to be selected for an IS volume.
Chapter 6 CIM Solution This chapter describes the Fusion-MPT Common Information Model (CIM) Solution and explains how it is used to monitor storage components, including mirrored and striped volumes, in multiple systems on a network. This chapter contains the following sections: 6.1 • Section 6.1, “Description” • Section 6.2, “CIM Browser Window Description” • Section 6.3, “CIM Installation Instructions for Windows” • Section 6.
The latest version of the CIM Solution is available at this LSI Logic web site: http://support.megaraid.com/support/dloadcenter.html Follow these steps to download it: 1. Select SCSI Adapters from the drop-down list and click the arrow to the right of the list. 2. On the next screen, select LSI20320-R, LSI21320-R, or LSI22320-R from the drop-down list. 3. Select Miscellaneous for the file type, and click Next>. 4.
6.1.2 Installation and System Requirements The installation and system requirements for the CIM installation are: • • For Windows systems: – Windows NT version 4.0, service pack 6 or above – Windows 2000, service pack 2 or above – Windows XP – Windows Server 2003 – Windows .NET For Linux systems: – SuSE Linux version 7.0 or 8.0 – SuSE Linux Enterprise Server version 7 – Red Hat Linux versions 7.3, 8.0, or 9.0 – Red Hat Advanced Server version 2.
6.2 CIM Browser Window Description This section describes the CIM Browser window. 6.2.1 Connect Menu Options The Connect menu is in the upper left corner of the CIM Browser window. Table 6.1 describes the Connect menu options. Table 6.1 Connect Menu Option Description Option Description Connect Connects the computer running the CIM Browser to a single computer that is running the CIM Provider. Enter either the IP address or the host name of the computer to which you want to connect.
• A yellow exclamation mark icon indicates that the device has encountered a problem and its status is shown in the “status” text label. A yellow question mark icon indicates that the device has encountered a problem and its status cannot be determined. • A red status icon indicates that the device has encountered a severe error condition. On the IM/IS Volume and Physical Disk levels, the CIM Browser displays a floppy disk icon if the media is present.
Figure 6.1 Hardware Device Tree Structures a) SCSI Hardware Device Tree Network Host Name SCSI Controller Storage Device Storage Device b) SCSI with IM/IS Hardware Device Tree Network Host Name SCSI Controller IM/IS Volume Storage Device Storage Device c) FC Device Tree Network Host Name FC Controller Loop Storage Device Storage Device 6-6 CIM Solution Version 1.0 Copyright © 2003 by LSI Logic Corporation. All rights reserved.
Table 6.2 Device Tree Description Device Tree Level Description Network This level displays the CIM Browser welcome window. Host Name This level displays the name of the system that the CIM Provider is running on and that the CIM Browser is monitoring. The CIM Browser displays a window that provides information about the system that the CIM Provider is running on. The “System Connection” option usually reads “ok.
6.3 CIM Installation Instructions for Windows This section describes a Windows installation of the CIM Solution. 6.3.1 Installing the CIM Solution Follow these steps to install the CIM Solution 1. Double-click on the install.htm program that you downloaded from the LSI Logic web site. A “Security Warning” window appears. You must grant additional privileges to the InstallAnywhere so that it can complete the installation. 2. Click on Yes. 3. Click on Start Installer for Windows... InstallAnywhere begins.
6.4 CIM Installation Instructions for Linux This section describes a Linux installation of the CIM Solution. 6.4.1 Installing the CIM Solution Follow these steps to install the CIM Solution: 1. Unzip the CIM package after downloading it. 2. Double-click on the install.htm program that you downloaded from the LSI Logic web site. A “Security Warning” window appears. You must grant additional privileges to the InstallAnywhere to complete the installation. 3. Click on Yes. 4.
6-10 CIM Solution Version 1.0 Copyright © 2003 by LSI Logic Corporation. All rights reserved.
Appendix A Using the DOS-Based Configuration Utility This appendix describes how to use the DOS-based configuration utility (CU) to create Integrated Mirroring (IM) and Integrated Striping (IS) volumes. Although the same utility is used to set up both IM and IS volumes, the two kinds of configuration are explained in separate sections (A.4 and A.5). This is done because IM configuration and IS configuration use somewhat different command line options and have different default settings.
A.2 • Member disks of an IM or IS volume must be connected to the same channel of the same Fusion-MPT controller, and the controller must be in the BIOS boot order. • Member disks must be non-removable, single-LUN disks that support 512-byte sectors, wide synchronous transfers, Qtag’d I/Os, and a unit serial number. The disks must support SMART, and they must be minimally compliant with the SCSI-2 standard.
The DOS-based CU can use DOS input redirection to read configuration commands from a file specified on the command line. It can also use DOS output redirection to write status messages to a file instead of displaying them on the monitor. A.3 Rules for Command Line Options Here are some general rules for using the DOS-based CU command line options: A.4 • Each command line must start with mptpsir and must include at least one option. • No spaces are allowed between an option and an option value.
• Create a “custom” three- to six-disk mirrored volume, including an optional hot spare (/rte option, followed by /c for SCSI controller and /t for each disk). Note: A.4.1 You must list the /rte option first to indicate that the volume will have three or more mirrored disks. Command Line Options This section lists and explains all the DOS-based CU command line options that are used to create, delete, and reconfigure an IM volume. See Section A.4.
/ad – Action data, 1 to 4 hex digits. This option changes the default create volume behavior. The Action data definitions are: 0x0001 - Do not initialize disks when volume is created. 0x0002 - Low-level initialization. Zero initialize beginning and end of disks in volume. /a – Automatic create. Creates an IM volume with one primary disk and one secondary mirrored disk, using disks on the lowest numbered Fusion-MPT controller with at least two disks that don’t have defined partitions.
A.4.1.5 Changing Defaults for Newly Created Volumes /vi – Vendor Identification (logical drive inquiry data) - 8 ASCII characters required /pi – Product Identification (logical drive inquiry data) - 16 ASCII characters required /pr – Product Revision (logical drive inquiry data) - 4 ASCII characters required /io – Offset within inquiry data to start saving in non-volatile memory for later access. Two offsets can be specified, but each instance of this option requires the /is option.
0x0008 – High Priority Resync Enabled 0x0010 – A.4.2 Enable firmware to replace last two bytes of Product ID in inquiry data when an inquiry is sent to the IM volume’s logical drive. Making Manufacturing Settings Read Only You can make the manufacturing settings read-only by changing the PageType field for the Fusion-MPT Configuration Page, Manufacturing Page 4. Important: A.4.3 Making this page read-only disables the /vi, /pi, /pr, /io, /is, and /vs options.
A.4.4 Examples of Command Line Usage This section shows how various DOS-based CU command line options are used for mirrored volumes. A.4.4.1 Creating a Custom Mirrored Volume At least two targets must be listed with the /t option. Other options can be used on the same command line as the create options, to override the defaults.
A.4.4.3 Erasing Disk(s) Example 1 – Erase the disk with SCSI ID 5 on Controller 1. mptpsir /c1 /t5 /e Example 2 – Erase all disks on Controller 2. mptpsir /c2 /eall A.4.4.4 Replacing Manufacturing Defaults Example 1 – Use OEM-specific vendor, product, and revision information for the logical drive ID of the mirrored volume.
A.5 Configuring an IS Volume with the DOS-Based CU There are two basic ways to create an IS volume with the DOS-based CU (Create options are explained in Section A.5.1.1, and specific command line examples are included in Section A.5.4, “Examples of Command Line Usage,” page A-13): • Have the CU create the volume automatically (/a option). • Create a “custom” two- to six-disk striped volume by specifying a SCSI controller (/c option) and the SCSI target ID of each member disk (/t option for each disk).
/ad – Action data, 1 to 4 hex digits. This option changes the default create volume behavior. The Action data definitions are: 0x0001 - Do not initialize disks when volume is created. 0x0002 - Low-level initialization. Zero initialize beginning and end of disks in volume. /a – A.5.1.2 Automatic create - Creates an IS volume, using disks on the lowest numbered Fusion-MPT controller with at least two disks that don’t have defined partitions. Up to 6 disks are automatically selected for the IS volume.
this option requires the /is option. One possible use of this option is to save FRU data for the drive. /is – Size, in bytes, to save in non-volatile memory of inquiry data from offset given in the /io option. /vs – Set the VolumeSettings parameter (1- to 4-digit hex number). See Section A.5.1.7, “Volume Setting Definitions.” A.5.1.6 Miscellaneous Options /? – Display available Help options /h – Display available Help options /nr – No automatic reboot after exit.
A.5.3 A.5.4 IS Parameter Defaults for Fusion-MPT SCSI Controllers • Disk Write Cache ENABLED • Volume ENABLED • Disk Offline when SMART error DISABLED • Product ID Suffix ENABLED • No Inquiry Data saved from IS disks • Controller 0 • Size defaults to maximum allowable by disks selected, minus a disk coercion factor. The disk coercion factor allows disks of different sizes within the same disk class to work for a striped logical drive.
mptpsir /rts /i < c:\inputfile A.5.4.2 Deleting an IS Volume Example 1 – Delete the IS volume. mptpsir /rts /d A.5.4.3 Erasing Disk(s) Example 1 – Erase the disk with SCSI ID 5 on Controller 1. mptpsir /rts /c1 /t5 /e Example 2 – Erase all disks on Controller 2. mptpsir /rts /c2 /eall A.5.4.4 Replacing Manufacturing Defaults Example 1 – Use OEM-specific vendor, product, and revision information for the logical drive ID of the IS logical drive.
Customer Feedback We would appreciate your feedback on this document. Please copy the following page, add your comments, and fax it to us at the number shown. If appropriate, please also fax copies of any marked-up pages from this document. Important: Please include your name, phone number, fax number, and company address so that we may contact you directly for clarification or additional information. Thank you for your help in improving the quality of our documents.
Reader’s Comments Fax your comments to: LSI Logic Corporation Technical Publications M/S E-198 Fax: 408.433.4333 Please tell us how you rate this document: Integrated RAID User’s Guide. Place a check mark in the appropriate blank for each category.