bx="0.150" by="0.060" wx="0.3127" wy="0.329" wY="80"
external="FALSE"/>
</calibration_info>
</calibration>
</studiocal>
Tento druhý príklad dáva monitoru pokyn na kalibráciu dvoch predvolieb, prvej s primárnymi zložkami BT.
709, bielym bodom D65 a gamou BT.1886. Druhá sa bude kalibrovať s primárnymi zložkami DCI-P3, bielym
bodom P3 a gamou 2,6. Obe kalibrácie ukladá na miesto pamäte od výrobcu.
<?xml version="1.0" encoding="ISO-8859-1"?>
<!--BT.709/BT.1886 calibration-->
<studiocal>
<calibration entries="2">
<calibration_info>
<preset num="3" name="BT.709" store="factory"/>
<gamma value="bt1886"/>
<target_primaries rx="0.640" ry="0.330" gx="0.300" gy="0.600"
bx="0.150" by="0.060" wx="0.3127" wy="0.329" wY="80"
external="FALSE"/>
</calibration_info>
<calibration_info>
<preset num="5" name="DCI P3" store="factory"/>
<gamma value="2.6"/>
<target_primaries rx="0.680" ry="0.320" gx="0.265" gy="0.690"
bx="0.150" by="0.060" wx="0.314" wy="0.351" wY="48"
use_uv="false" external="false"/>
</calibration_info>
</calibration>
</studiocal>
Generovanie prolu ICC
V niektorých pracovných postupoch sa vyžaduje prol ICC kalibrovanej predvoľby. Tento prol môžete
generovať pomocou tagu save_icc. Tento tag dáva monitoru pokyn na výpočet prolu ICC pre kalibrovanú
predvoľbu a jeho zápis na jednotku USB ash obsahujúcu súbor StudioCal XML. Výpočet prolu ICC vyžaduje,
aby sa vykonali ďalšie meraniach po kalibrácii, takže kalibrácie pomocou spektrorádiometra môžu trvať
výrazne dlhšie.
Tento tag obsahuje jeden atribút a je štruktúrovaný nasledovne:
<save_icc value="TRUE|FALSE"/>
Základné kalibračné tagy 81