Product Data Sheet / Brochure
Table Of Contents
QuickSpecs
HPE ProLiant DL385 Gen10 Plus Server
Technical Specifications
Page 42
System Unit
Dimensions
• SFF Drives:
8.73 x 44.54 x 71.1 cm 3.44 x 17.54 x 28 in
• LFF Drives:
8.73 x 44.54 x 74.9 cm 3.44 x 17.54 x 29.5 in
Weight (approximate)
Minimum:
15.1 kg / 33.25 lbs with 1
hard drive
Maximum:
19.7 kg / 43.50 lbs with
24 hard drives
Minimum: 8 SFF chassis with 1x SFF HDD and 7 HDD blanks, 2x Drive Bay blanks, 1x processor
including standard heatsink, 1x power supply (plus blank), 1x Smart Array, 1x Riser installed, cables
for the above)
Maximum:
24.7 kg / 54.5 lbs with 12
hard drives
Minimum:
17.3 kg / 38.25 lbs with 1
hard drive
Maximum: 12 LFF hard drives (no rear drives), 2x processors, 2x power supplies, 1x Smart Array, 2x
Risers installed)
Input Requirements (per power supply)
Rated Line Voltage
• 100 to 120 VAC
•
200 to 240 VAC
BTU Rating
Maximum
•
For 800W Power Supply: 3207 BTU/hr (at 100 VAC), 3071 BTU/hr (at 200 VAC), 3112 BTU/hr (at 240 VAC) for China
Only
• For 500W Power Supply:
1979 BTU/hr (at 100 VAC), 1911 BTU/hr (at 200 VAC), 1965 BTU/hr (at 240 VAC) for China
Only
Power Supply Output (per power supply)
Rated Steady-State Power
• For 1400W Power Supply: 1400W (at 240 VAC), 1400W (at 240 VAC)
• For 800W Power Supply: 800W (at 100 VAC), 800W (at 240 VAC), 800W (at 240 VAC) input for China only
• For 500W Power Supply: 500W (at 100 VAC), 500W (at 240 VAC), 500W (at 240 VAC) input for China only
Maximum Peak Power
• For 1400W Power Supply: 1400W (at 200 to 240 1VAC), 1400W (at 240 VAC) input for China only
•
For 800W Power Supply: 800W (at 100 to 127 VAC), 800W (at 200 to 240 1VAC), 800W (at 240 VAC) input for China only
•
For 500W Power Supply: 500W (at 100 to 127 VAC), 500W (at 200 to 240 VAC), 500W (at 240 VAC) input for China only
System Inlet Temperature
Standard Operating Temperature
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea
level
to a maximum of 3050 m (10,000 ft), no direct sustained sunlight.
Maximum rate of change is 20°C/hr (36°F/hr). The upper limit
and rate of change may be limited by the type and number of options installed.
System performance during standard operating support may be reduced if operating with a fan fault or above 30°C (86°F).